HID Vertx CS V100 Quick Installation Manual Download Page 5

 

VertX V100 (CS) Quick Installation Guide 

 

 

 

 

 

August 2005 

Page 5 of 9 

2005 © HID Corporation. All rights reserved.

 

 

Pin # 

P7 

1 +12VDC 
2 Ground 

Bat Fail - 

Bat Fail + 

AC Fail - 

AC Fail + 

7 Tamper 

8 Tamper 

 

Pin # 

V100 P1 

V100 P4 

Reader Power 

Shield Ground 

2 Ground 

Hold 

Data 0 / Data 

Beeper 

Data 1 / Clock 

Red LED 

Data Return 

Green LED 

Green LED 

Data Return 

Red LED 

Data 1 / Clock 

Beeper 

Data 0 / Data 

9 Hold 

Ground 

10 

Shield Ground 

Reader Power 

Step 2  Hardware Installation 

2.1 Mounting 

Instructions 

1.  The V100 should always be mounted in a secure area. 
2.  Mount the V100 using the four mounting screws (provided) or other appropriate fasteners. Place the 

fasteners in the corner holes of the base. 

3.  The V100 panel can be stacked with or without the cover. Do not remove the plastic base. Make sure 

to position the V100 panel in such a way as to provide room for wiring, air-flow and cable runs.  

2.2 Wiring 

VertX 

 

1. 

Power and Alarm input connections: 

Connect power by providing 12VDC to the 

P7

 connector. 

+12VDC goes to 

Pin 1

 and Ground on 

Pin 2

. The Bat Fail, AC Fail, and Tamper switch inputs are 

wired as shown in the table. Connect the Bat Fail and AC Fail inputs to battery low/failure and AC 
failure contacts provided on the power supply. Connect the Tamper input to a tamper switch on the 
enclosure. 

 

 
 
 

 
 
 
 

2. 

Reader Connections

:  Connect Wiegand or 

clock-and-data interfaces to the V100 using 
the connection table shown. You can 
connect up to 10 signal lines for the reader. 
Use as many of the signal lines as required 
for your reader interface.  

Note:

 Connect the data return line to the 

same ground as the reader power if the 
reader is not powered by the VertX units 
12VDC. 
 

 

CAUTION: Connectors on the V100 sides are positioned to be mirror images and are not 
interchangeable once the installation is complete. Therefore, you cannot unplug the connector from 
one side of the board and plug it into the corresponding connector on the other side.

 

Summary of Contents for Vertx CS V100

Page 1: ...proprietary information which may not be duplicated published or disclosed to others or used for any purpose without written permission from HID Corporation 2004 HID Corporation All rights reserved Do...

Page 2: ...TART VERTX CS V100 Door Reader Interface Panel 1 Introduction 3 Parts List included 3 Product Specifications 3 Cable Specifications 3 Overview 4 Step 1 Preparations 4 1 1 What you need before getting...

Page 3: ...ic or Mylar cover 1 Mounting screws 4 2 2K EOL resistors 4 Quick Installation Guide 1 Installation Wiring Diagram Example 1 Note A VertX V1000 Access Controller is required Product Specifications Desc...

Page 4: ...read through this guide CAUTION The V100 is sensitive to Electrostatic Discharges ESD Observe precautions while handling the circuit board assembly by using proper grounding straps and handling precau...

Page 5: ...ir flow and cable runs 2 2 Wiring VertX 1 Power and Alarm input connections Connect power by providing 12VDC to the P7 connector 12VDC goes to Pin 1 and Ground on Pin 2 The Bat Fail AC Fail and Tamper...

Page 6: ...re Installation Worksheet found in the back of the HID VertX V1000 Quick Install guide 5 Output Connections All Output connections are used for general purpose controls The following table shows where...

Page 7: ...lly Closed NC unsupervised no EOL resistors All other input points are defaulted for NO switches and are unsupervised no EOL resistors Any input can be configured as a supervised input They can be con...

Page 8: ...Fail P2 Pins 1 2 7 P7 Pins 4 3 Batt Fail P7 Pins 4 3 Batt Fail P2 Pins 3 4 8 P2 Pins 5 6 9 P4 Pins 10 9 10 P4 Pins 8 7 11 P4 Pins 6 5 12 P4 Pins 4 3 13 P4 Pins 2 1 14 P5 Pins 6 5 15 P5 Pins 4 3 16 P5...

Page 9: ...h case the user will be required to correct the interference at his own expense Class B Digital Devices FCC Compliance Statement This equipment has been tested and found to comply with the limits for...

Reviews: