2.1.1 Jumpers and jacks

The LP1502 processor hardware interface is configured using jumpers to setup the reader port power and 
end of line termination.

Jumpers

Set at

Description

J1

N/A

Factory use only

J2

N/A

10-Base-T/100Base-Tx Ethernet connection (Port  0)

J3

N/A

Factory use only

J4

N/A

N/A

J5

OFF

RS-485 EOL Terminator is OFF

ON

RS-485 EOL Terminator is ON

J6

N/A

Micro USB port (2.0)

J7

Reader power select. See caution below.

12V

12 V DC at reader ports

PASS

VIN "Pass Through" to reader ports

J8

N/A

microSD card

J10-1

N/A

Remote Status LED #1.

1

J10-2

N/A

Remote Status LED #2.

1

J10-3

N/A

Remote Status LED #3.

1

J10-4

N/A

Remote Status LED #4.

1

J19

OFF

Backup battery  is OFF.

ON

Backup battery is ON. See 

Memory and real time clock backup battery

1. Observe polarity connection to LED. External current limiting is not required.

 

Caution:

  Install jumper J7 in the 12 V position 

ONLY

 if the input voltage (VIN) is greater than 20 V DC. Failure 

to do so may damage the reader or LP1502.

PLT-05244, A.3

8

June 2021

Powering

Trusted Identities

HID Mercury™ LP1502 Controller

Installation and Specifications

Summary of Contents for Mercury LP1502

Page 1: ...HID Mercury LP1502 Controller Installation and Specifications PLT 05244 A 3 June 2021 HID Mercury LP1502 Controller Installation and Specifications Powering Trusted Identities...

Page 2: ...chnical Support www hidglobal com support Americas and Corporate Asia Pacific 611 Center Ridge Drive Austin TX 78753 USA Phone 1 866 607 7339 19 F 625 King s Road North Point Island East Hong Kong Pho...

Page 3: ...Section 01 Powering Trusted Identities Overview...

Page 4: ...eader that uses TTL D1 D0 Clock Data F 2F standard or supervised or 2 wire RS 485 device signaling OSDP reader for example and also provides tri state LED control and buzzer control one wire LED mode...

Page 5: ...Section 02 Powering Trusted Identities LP1502 wiring and setup...

Page 6: ...t 2 wire RS 485 TB3 2 TR B 1 TB3 3 TR A 1 TB4 1 IN2 Input 2 TB4 2 IN2 TB4 3 IN1 Input 1 TB4 4 IN1 TB5 1 IN4 Input 4 TB5 2 IN4 TB5 3 IN3 Input 3 TB5 4 IN3 TB6 1 IN6 Input 6 TB6 2 IN6 TB6 3 IN5 Input 5...

Page 7: ...Normally open contact TB10 2 C Out 1 Common contact TB10 3 NC Out 1 Normally closed contact TB10 4 NO Out 2 Normally open contact TB10 5 C Out 2 Common contact TB10 6 NC Out 2 Normally closed contact...

Page 8: ...eader ports PASS VIN Pass Through to reader ports J8 N A microSD card J10 1 N A Remote Status LED 1 1 J10 2 N A Remote Status LED 2 1 J10 3 N A Remote Status LED 3 1 J10 4 N A Remote Status LED 4 1 J1...

Page 9: ...FF Bulk Erase prompt mode at power up See Bulk erase configuration memory X X X ON Makes the LP1502 report and function like an EP1502 To be used in situations where the host software has not been upd...

Page 10: ...D 1 is on for about 15 seconds while LP1502 boots up 3 Change DIP switches 1 or 2 to OFF Within 10 seconds after LEDs 1 and 2 and LEDs 3 and 4 start flashing alternately at a rate of 0 5 seconds If th...

Page 11: ...g The LP1502 controller communicates with the host via the on board Ethernet 10 BaseT 100Base TX port and or the USB port 2 0 with an optional USB to Ethernet adapter The serial I O device communicati...

Page 12: ...uires two 2 conductor cables Use one cable for power 18 AWG and one cable for communication 24 AWG with drain wire and shield Note For OSDP cable lengths greater than 200 ft 61 m or EMF interference i...

Page 13: ...al reader 2 Wiegand or Clock Data installation Typical unsupervised F 2F reader Typical supervised F 2F reader Jumper D1 to LED on supervised F 2F reader Inputs on supervised F 2F readers may be unsup...

Page 14: ...voltage A supervised input circuit requires two resistors be added to the circuit to facilitate proper reporting The standard supervised circuit requires 1k 1 resistors and should be located as close...

Page 15: ...a diode is used to protect the relay Wire should be of sufficient gauge to avoid voltage loss Diode selection n Diode current rating 1x strike current n Diode breakdown voltage 4x strike voltage n Fo...

Page 16: ...battery status Off line 20 ON On line 80 ON Double flash if battery is low 2 Host communication activity Ethernet or Micro USB port 3 Internal SIO communication activity 4 External SIO communication...

Page 17: ...is shipped from the factory with a default login account which is enabled when DIP 1 is moved from OFF to ON See DIP switches The default login user name admin and password password will be available...

Page 18: ...Section 03 Powering Trusted Identities Specifications...

Page 19: ...rm C with dry contacts Normally open contact NO contact 5 A 30 V DC resistive Normally closed contact NC contact 3 A 30 V DC resistive Reader interface Power jumper selectable 12 V DC 10 regulated 300...

Page 20: ...anties or implied warranties and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose Returns must be accompanied by a Return Material Authori...

Page 21: ...Added reader power select table in 2 7 Reader wiring A 2 January 2021 Add J19 Battery backup call out to the hardware diagram A 1 October 2020 Initial release A 0 PLT 05244 A 3 21 June 2021 Powering...

Page 22: ...a Pacific 19 F 625 King s Road North Point Island East Hong Kong Europe Middle East Africa 3 Cae Gwyrdd Green Meadow Springs Cardiff CF15 7AB United Kingdom Brazil Condom nio Business Center Av Ermano...

Reviews: