Replacing the Electromagnet

HP-

100

/

120

REPLACING THE ELECTROMAGNET

Be sure to unplug the pump unit. 

When  performing  replacement  work,  the  pump  body  may  still  be  hot  and  you  could 
get burned. So please wait until the pump has cooled before handling. 

Be  sure  to  remove  the  chamber  block  and  the  actuating  rod  before  replacing  the 
electromagnet. 

It  is  better  to  let  an  experienced  technician  handle  the  soldering  process.  Take 
precautions against getting burned.

STEP

1

STEP

1

Cut  the  wire  from  the  terminals  on  electromag-

nets with nippers. 

●It is recommended that you make a note of the wiring.

STEP

2

STEP

2

Loosen the screw, fixing SP switch and remove it . 

(There  are  hexagonal  nuts  at  SP  switch  side.  Be 

sure not to lose them as they fall inside the unit.)

STEP

3

STEP

3

Remove the nuts by the box driver. 

(8mm wrench) 

Pull out the electromagnet from the pump body.

CAUTION

! 

REMOVAL OF ELECTROMAGNET

Summary of Contents for hp-100

Page 1: ...g Sound Absorber Lap Casing Block A Valve Chamber packing Casing Block B Valve Diaphragm Ring Diaphragm Diaphragm Base Frame Cover SP Switch Safety pin Locking collar Electromagnet Actuating Rod L Tub...

Page 2: ...ore be sure to remove your watch and any other precision machines before operation as they may be affected by the strong magnetic force Do not put the actuating rod close to a magnetic card magnetic d...

Page 3: ...must be broken to prevent any further damage to the pump Be sure all broken pieces are removed from the unit See Step 15 Remove the 4 screws holding the chamber block and the casing block 4 screws on...

Page 4: ...the valves from the casing B If it is difficult to separate them insert the tip of a flatblade screwdriver into the clearance Pull out the valves as they can be removed easily STEP 10 STEP 10 Insert e...

Page 5: ...r otherwise U lock nut may work loose and cause malfunction Insert the actuating rod into the machine body Be sure to fit the positioning boss on the diaphragm base into the concave part of the frame...

Page 6: ...cking collar from the other side of the terminal and insert it until it clicks STEP 18 STEP 18 This completes the replacement of the safety pin procedure Make sure the gap between L shaped lever and t...

Page 7: ...20 STEP 21 STEP 21 Install the sound absorber Place the upper housing back on body Be extremely careful not to catch the sound absorber on the upper housing Fasten it with the bolts Then place the fi...

Page 8: ...It is better to let an experienced technician handle the soldering process Take precautions against getting burned STEP 1 STEP 1 Cut the wire from the terminals on electromag nets with nippers It is r...

Page 9: ...e terminals Solder the wires to the terminals The wire requires a soldered connection Mount new the electromagnets in the unit Tighten up nuts with nut driver STEP 7 STEP 7 This completes the electrom...