PAR Description
-3
+10
-30
-12
-25
-5
-20
-15 PAR
0
= Intervals – defr. will be activated once the instrument run for time d0;
1
= Intervals – defr. will be activated once the compressor has
switched on for time d0;
2
= Intervals – defr. will be activated once the evaporator temp. has altogether been below temp. d9 for time d0;
3
= Adaptable - defrosting will be activated when (condition 1) the evaporator temp. will be below temp. d22 and the compressor will
altogether be switched on for time d18 or when (condition 2) the evaporator temp. will fall below temp. d19; 4= real time – def. will be
activated at the times established in parameters Hd1 ... Hd6
[11]
d9
evaporator temp. is higher than that at which the defrost interval counter is suspended
0
0
0
0
d9
d11
defrosting alarm switches off once maximum time limit has been reached (code “dFd”; if P3 = 1 /
1=YES
0
0
0
0
d11
dA
minimum compressor on duration on activation of defrosting so that they may be activated [12]
0
0
0
0
dA
d16
0
0
0
0
d16
d17
number of evaporator temp. values used for the calculation of the relative average (for the defrost activation; if d8 = 3)
4
4
4
4
d17
40
40
40
40
d18
d19
3
3
3
3
d19
d20
180 180 180 180
d20
d21
200 200 200 200
d21
d22
0
0
0
0
d22
d23
1
1
1
1
d23
A0
Temperature associated with the min. temp. alarma
[13]
0
0
0
0
A0
A1
temp. below which lower temp. alarm is activated;
-5
-20
-50
-50
A1
A2
kind of lower temp. alarm
0= NO Alarm;1=relative to SetPoint; 2=absolute
1
1
1
1
A2
A4
temp. above which the upper temp. alarm is activated
10
20
10
10
A4
A5 kind of upper temp. alarm
0= NO Alarm1=relative to SetPoint; 2=absolute
1
1
1
1
A5
A6
upper temp. alarm delay since you turn on the instrument
[4]
240 240 240 240
A6
A7 temp. alarm delay
90
15
90
90
A7
A8
upper temp. alarm delay since the end of the defrost
[14]
15
15
15
15
A8
A9
delay in maximum temp. alarm
(15)
15
15
15
15
A9
Ab
Differential of parameters A1, A4 and F1 / diff ALL e vent evap (°C)
4
4
4
4
Ab
A13 Delay in minimum temp. Alarm since end of CONTINUOUS COLD function
120 120 120
A13
F0 evaporator fan activity during normal operation
1
5
1
1
F0
predripping duration (the compressor will remain switched off, the defrosting output will be activated and the evaporator fan will
remain
switched off
d18 defrost interval (if d8 = 3 and for condition 1)
evaporator temp. above which the defrost is activated (relative to the evaporator temp. average, or “evaporator temp. average - d19”) (if
d8 = 3 and for condition 2)
minimum consecutive time the compr. must be switched on such as to provoke the defrost activation
minimum consecutive time the compressor must be switched on after the insturment switches on (on condition that the difference “cell
temp. - working setpoint” is higher temp. r7) and after function Overcooling is activated such as to provoke the defrost activation
evaporator temp. above which the defrosting interval is suspended (relative to the evaporator temp. average, or “evaporator temp.
average + d22”) (if d8 = 3 and for condition 1)
evaporator temp. average increase during function Energy Saving (for defrost activation; if d8 = 3)