background image

   

   

©HiB Copyright: No part of this document may be reprinted or duplicated without HiB consent. All sizes and measurements are approximate, but we do try and make sure they are as accurate as possible. In the interest of continuous 
product development, HiB reserves the right to alter specifications as necessary. E & OE.

T:

 +44 (0)20 8441 0352    

F: 

+44 (0)20 8441 0219    

E: 

[email protected]    

hib.co.uk 

Building 3, North London Business Park, Oakleigh Road South, New Southgate, London. N11 1GN

WEEE compliance

Must not be mixed with 
general household 
waste

Timer System

Wiring diagram for lamp

The timer circuit is under mains Voltage. Ensure mains power supply is switched off before making 

any adjustments.

The fan is operated by turning on the wall 
switch. When the switch is turned off the fan 
will continue to operate within the set perios 
of time. Adjustable between 2-30mins. This 
can be adjusted by turning the potentionme-
ter T clockwise to increase and anticlockwise 
to decrease the run time.

Cool White and Warm White illuminated fans.

ONLY 

use the 

screwdriver 

provided 

to adjust 

the timer 

setting.

AC in

DC out

Live is Red

Live supply is Red or Brown

Neutral supply is Blue or Black

Neutral is Black

Maintenance

In order to maintain the safe and effective operation of the fan regular maintenance must be performed

Fan maintenance is to be performed only after the fan is disconnected from the mains power supply. 
This includes periodic cleaning of the surface of dust and dirt. 

All surfaces should be cleaned with a diluted detergent and a soft cloth. Avoid water dripping on the electric 
components. Wipe the surfaces dry after cleaning.

Aftercare service - In the unlikely event that this product should fail, please contact HiB customer services. 
The details are shown below.

This product contains a light source of energy efficiency class E

Electrical Information

Summary of Contents for 33600

Page 1: ...ns only Installations must be made in accordance with the current IEE wiring regulations and relevant building regulations Thank you for purchasing this HiB product We recommend that all electrical bathroom products should only be fitted by a suitably qualified Part P registered electrician Suitable for installation in zones 2 outside zones Fig 1 Electrical safety information Ensure mains power su...

Page 2: ... supplied 5 Attach the flexible ducting with the metal hose clamps Ensure the ducting has a smooth flow towards the motor body Follow a simular procedure for the outside wall grille Extra ducting may be used to extend the distance to the external grille but the performance will be reduced Install the Turbo Inline fan within the loft or ceiling space DO NOT COVER the motor or LED driver with loft i...

Page 3: ... Grey See image left Alternatively if you only have a two core cable you can wire the fan up as follows N Black or Blue L Brown now you can loop from the L to the LT This does bypass the timer function The fan will now only operate as an on off fan See image left Bridge L LT Only if permanent live is not available L1 L2 C LT L N N L LOOP Power Supply Wall Switch Ceiling Rose Fan Earth connection h...

Page 4: ...rios of time Adjustable between 2 30mins This can be adjusted by turning the potentionme ter T clockwise to increase and anticlockwise to decrease the run time Cool White and Warm White illuminated fans ONLY use the screwdriver provided to adjust the timer setting AC in DC out Live is Red Live supply is Red or Brown Neutral supply is Blue or Black Neutral is Black Maintenance Inordertomaintainthes...

Reviews: