background image

hib.co.uk

5

4.  Wire the fan as per fig. C below. 

5.  Amend the timer setting, if desired, following the process on page 6. Replace cover using a 

suitable screw driver.  

6.  On Illuminated versions

 (32600, 33800, 32700 & 33700) 

the mains supply should be connected 

to the LED driver as per the wiring diagram for lamp (Fig. D).

7.  Fix the external grille to the soffit in the same way as the ceiling fascia with 4 screws.
8.    For illuminated Cyclone vents, follow the wiring diagram below (Fig. D). 

QF - Circult Breaker
ST - External Switch (e.g. light switch)

Wiring Diagram For Lamp 

(32600, 33800, 32700 & 33700 only)

N

L

ST

QF

N

L

LT

LI

Do Not Use

~

AC in

DC out

Live is Red

Live supply is Red or Brown

Neutral supply is Blue or Black

Neutral is Black

 (Fig. D)

 (Fig. C)

Summary of Contents for 32600

Page 1: ...d Art no 33400 Thank you for purchasing this HiB product Please read through these instructions carefully and refer back to them during installation to ensure that your product is fitted safely and that it retains its high quality finish Please retain this leaflet for future reference Before drilling ensure there are no hidden cables or pipes in the wall Please see Fig 1 on the back page for detai...

Page 2: ...etween the breaker contacts on all poles not less than 3 mm Check the fan for any visible damages of the impeller and the casing before starting installation The casing internals must be free of any foreign objects which can damage the impeller blades Misuse of the product or any unauthorized modification is not allowed Take steps to prevent ingress of smoke carbon monoxide and other combustion pr...

Page 3: ...ings not supplied 5 Attach flexible ducting with the metal hose clamps Ensure that the ducting has a smooth flow towards the motor body to minimise air resistance Follow a similar procedure for the outside wall grille Extra ducting may be used to extend the distance to the external grille but performance will be reduced Mounting Fan unit 1 Install the Cyclone Inline fan within the loft or ceiling ...

Page 4: ...th the metal hose clamps Ensure there is a minimum of 1m straight ducting between fascia and fan 1 Using a screw driver remove cover 2 Using a screw driver remove cable grip 3 Feed cable through hole replace grip Electrical Connection Ensure the mains power supply to which the fan is being connected is turned off This product is designed to be connected to an on off switch outside the bathroom or ...

Page 5: ...iver as per the wiring diagram for lamp Fig D 7 Fix the external grille to the soffit in the same way as the ceiling fascia with 4 screws 8 For illuminated Cyclone vents follow the wiring diagram below Fig D QF Circult Breaker ST External Switch e g light switch Wiring Diagram For Lamp 32600 33800 32700 33700 only N L ST QF N L LT LI Do Not Use AC in DC out Live is Red Live supply is Red or Brown ...

Page 6: ...the timer period set by the timer from 2 to 30 minutes To adjust the run on timer rotate the control knob clockwise to increase and anti clockwise to decrease the off delay time respectively see below diagram Please note the adjustment should only be done without the fan running The set includes a specially designed plastic screwdriver for timer setting adjustments Only use the plastic screwdriver...

Page 7: ...ains power suppy Maintenance means periodic cleaning of the surface of dust and dirt All surfaces should be cleaned with diluted detergent i e washing up liquid and a soft cloth Scourers and scouring agents should not be used as these may cause damage to the surface of the product Avoid water dripping on the electric components Wipe the surfaces dry after cleaning Technical Information Power Input...

Page 8: ...es and measurements are approximate but we do try and make sure they are as accurate as possible In the interest of continuous product development HiB reserves the right to alter specifications as necessary E OE T 44 0 20 8441 0352 F 44 0 20 8441 0219 E sales hib co uk hib co uk Building 3 North London Business Park Oakleigh Road South New Southgate London N11 1GN Fig 1 Electrical Safety Informati...

Reviews: