5.3 Operating Orientation  

JCS jacks are designed so that the base plug (6) protrudes the jack body (5). This 
is to ensure that any load is borne by the steel base plate and not the aluminium 

jack body. If full support of the base plug can be achieved, the JCS jack can be used in any orientation. The 
jack must not be used with the base plug partially supported to prevent damage and/or injury. 

 

 

 

 

 

 

 

 

 

  The load bearing area is shown above, highlighted yellow. 

 

5.4 Placing the Jack 
 

  Carefully determine the jacking/loading point of the item to be lifted/moved, taking the following into 

consideration: 

1.  Make sure the jacking/loading point is strong enough to withstand the load that will be applied 

to  it, without  damaging  the object being lifted/moved. If necessary place suitable material 
between the load point and the jack ram to avoid damaging the structure to be lifted/moved. 

2.  Ensure the chosen loading point will not cause the structure to topple or shift unexpectedly 

when  the  piston  is  extended.  If  necessary  put  additional  safety  measures  in  place  (eg. 
Rigging, blocking) to limit any unexpected movement of the load. 

  Place the jack on a firm, level foundation capable of supporting the load to be lifted/moved, whilst 

fully supporting the jack base plug (6). Where necessary, use an additional support base of suitable 
material to support the jack and distribute the load evenly across its base. 

 

 

DO NOT 

position the jack by using the operating lever in the release valve. If the jack is to be placed 

some  distance  under  the  load,  use  the  operating  lever  in  the  operating  lever/quadrant  socket  to 
position the jack. 

   

ALWAYS

 ensure the jack’s piston contacts the load to be lifted as squarely as possible. 

Summary of Contents for JCS Series

Page 1: ...i Force website Hi Force reserves the right to make changes to this document at any time without notice This document assumes that the operator carrying out any operation with this product is trained...

Page 2: ...Contents 1 0 Inspection upon Receipt 3 2 0 Safety Precautions 3 3 0 Declaration of Conformity 5 4 0 Component Identification 5 5 0 Installation Setup 6 6 0 Operation 8 7 0 Maintenance and Storage 9 8...

Page 3: ...t Hi Force office or distributor Only qualified personnel should be allowed to operate hydraulic equipment If an operator has not been trained on high pressure hydraulic equipment and its safe usage c...

Page 4: ...se plug 6 and can support the load to be applied Where applicable use an additional support base to assist in supporting the load to be lifted Avoid lifting loads that are not central to the lifting p...

Page 5: ...ted and complies with the standards and declarations as set out in the Declaration of Incorporation Conformity DoI DoC The DoI DoC is included as Annex A to this instruction document and is supplied w...

Page 6: ...and returned to its proper operating condition Ensure the external surfaces are dirt free 5 2 Filling with Oil Hi Force JCS Jacks are despatched from the factory pre filled with oil and ready for use...

Page 7: ...ect being lifted moved If necessary place suitable material between the load point and the jack ram to avoid damaging the structure to be lifted moved 2 Ensure the chosen loading point will not cause...

Page 8: ...te the pump The piston will rise and lift push the load When the piston reaches full stroke the stop ring prevents the piston from rising further If you need to raise the load further than the rated s...

Page 9: ...a prolonged period it is advisable to apply grease to exposed metal surfaces Lubricate the pump rocker periodically NEVER store transport or lift a jack with its piston in the extended position 8 0 S...

Page 10: ...n binding Repair or replace jack e Jack seals leaking Repair or replace jack 2 Piston advances but will not hold a Load is too heavy for jack Use suitably rated jack b Piston seals leaking Repair or r...

Page 11: ...Instruction Manual OM JCS 01 Serial Number ALL 11 UK Head Office Hi Force Limited Prospect Way Daventry Northamptonshire NN11 8PL United Kingdom Tel 44 1327 301000 Fax 44 1327 706555 Email daventry hi...

Page 12: ...Numansdorp Netherlands Tel 31 85 902 8111 Email holland hi force com Hi Force Hydraulics Pty Ltd Midrand South Africa Tel 27 11 314 0555 Email south africa hi force com Hi Force Saudi Dammam Saudi Ar...