![Hi-Force HTWP Series Operating Instructions Manual Download Page 17](http://html1.mh-extra.com/html/hi-force/htwp-series/htwp-series_operating-instructions-manual_2128897017.webp)
Operating Instruction Manual:
OM-HTWP-ELECTRIC-01
Serial Numbers:
From: BP5141
17
6.2. Setting the Pressure (Torque)
Before setting the pump pressure it is necessary to determine what pump pressure will result in the torque
value required.
Use the tool-specific pressure-torque conversion chart provided with the torque wrench to determine the
pump pressure that corresponds to the required torque value.
The procedure for setting the pump pressure
MUST
be carried out with the torque tool
attached to the pump but
NOT
fitted onto a nut or bolt
The procedure for setting the pump pressure is as follows:
1. Loosen the wing nut below the adjustable relief valve knob and turn the relief valve knob [2]
fully anti-clockwise.
2. Turn the pump ON by pressing the green start button (1) on the motor control box (13). (
See figure
4.1
)
3.
Press and hold down the ‘advance button’ (12) on the pendant. The tool will advance and stop at its
maximum stroke, this is correct.
4. While holding the pump in advance mode, slowly turn the relief valve knob clockwise and watch as
the pump pressure on the gauge rises.
When the pressure reaches your desired value, stop turning the knob and allow the gauge to settle.
IMPORTANT:
The pressure must
ALWAYS
be adjusted from a lower pressure up to the target
value,
NEVER
down from a higher pressure to the target pressure.
5. Re-press the advance button on the pendant and slowly increase the pressure until the desired
pressure is achieved.
6. While holding the pump at the desired pressure, tighten the wing nut against the valve body. This
will lock in the pump pressure at the correct level for the required torque tool output.
7. Release the advance button and allow the tool to retract fully.
8. Cycle the pump one more time to confirm the correct pressure and ensure nothing changed while
fastening the wing nut.