INTRODUCTION 

The operating and maintenance procedures 
listed within this manual should be adhered to 
and will enable the operator to obtain 
maximum efficiency and reliability from the 
equipment. 
 

 

 

PRECAUTIONS 

Prior to connecting the hydraulic pump to any 
equipment, the user is to ensure that:- 

The working pressure of the hydraulic pump 

and the equipment to be operated are 
compatible. 

The reservoir pump capacity is adequate to 

operate the equipment throughout its range. 

The hydraulic oil specifications used within 

the pump and the equipment are compatible. 
 

TECHNICAL SPECIFICATION- HPX1500 

Working Pressure: 1500 Bar 
Total Oil Capacity: 1800 cm

3

 

Effective Oil Capacity: 1200 cm

3

 

Displacement/Pump stroke, Low-press: 20 cm

3

 

Displacement/Pump stroke, High-press: 1.0cm

Pumping Effort: 370N 
Weight: 6.5kg 
 

TECHNICAL SPECIFICATION- HPX1500 

Working Pressure: 2800 Bar 
Total Oil Capacity: 1800 cm

3

 

Effective Oil Capacity: 1200 cm

3

 

Displacement/Pump stroke, Low-press: 20 cm

3

 

Displacement/Pump stroke, High-press:  0.8cm

Pumping Effort: 370N 
Weight: 6.5kg 

RECOMMENDED OIL 

Hydraulic oil, viscosity class ISO 32 
 

Prior to use: 

Operate the handle with the Release valve 
open as shown in figure 1. This will assist in 
bleeding the pump of air trapped in the 
system. 
 
 
Figure 1: 
 

 

During test and operation of the pump it is 
recommended that a length of hose is either 
connected to a tool or terminated with a 
coupling and blanking plug is connected to 
the pump. 
This assists in moving a reasonable quantity of 
oil from the pump prior to pressurising and 
prevents air from gathering and being trapped 
in the system. 
 

Description of Pump Operation: 

A dual piston system which delivers low 
pressure or high pressure throughout the pump 
stroke. The system switches automatically 
between low and high pressure to ensure 
maximum efficiency whatever the load. 
 

Safety Feature: 

The pump is equipped with an internal tamper 
proof safety valve that regulates the maximum 

working pressure. The safety valve is set to the 
maximum pump working pressure and is 
factory pre-set. 
 

Installation 
General 

Always check that hoses, couplings, cylinders 
and tools, etc; that are connected to the 
pump are designed for use at a working 
pressure that equals or exceeds the maximum 
working pressure of the pump. 

Connecting the hydraulic hose 

Connect the hydraulic hose using a G 1/4" 
coupling, or use a Hi-Force quick coupling, 
tightening to a maximum torque of 40–50 
Nm.  Air can become trapped in the hydraulic 
system when you connect hoses and tools, and 
this can lead to problems with operation. Refer 
to the heading Bleeding the hydraulic system