background image

 

INSTRUCTION MANUAL – HYDRAULIC HAND PUMPS:  

Model Series: HP110, HP227-257, HP211-252D, HPX1500-2800

 

Hi-Force Limited – Prospect Way – Daventry – Northants NN11 8PL – United Kingdom 
Tel: +44(0) 1327 301000:  Fax: +44(0) 1327 706555: Website: www.hi-force.com  

Always

  operate  the  system  under  no  load 

condition prior to the actual lift to ensure that no 

air is trapped in the hydraulic circuit. 

Do not 

drop or place heavy objects on a 

hydraulic hose as this will cause internal 
damage to the hose which could result in 
rupture when the hose is pressurized and could 
result in serious damage to components, and 
possible serious personal injury to operating 
personnel. 
 

3.0 General Information:

 

HP110 – Single Speed Manual Operation Steel 
Construction Pump –Displacement: 2.9 cm

3

 per 

stroke- 700 bar maximum working pressure. 
 
HP227, HP257 – Two Speed Manual Operation 
Steel Construction Pump – Displacement: 1

st

 

Stage 12.9 cm

3 : 

2

nd

 Stage 2.3 cm

3

 - 700 bar 

maximum working pressure. 
 
HP245, HP245D – Two Speed Manual Operation 
Steel Construction Pump – Displacement: 1

st

 

Stage 113 cm

3 : 

2

nd

 Stage 4 cm

3

 - 700 bar 

maximum working pressure. 
 
HP211 – Two Speed Manual Operation 
Aluminium Construction Pump – Displacement: 
1

st

 Stage 12.9 cm

3 : 

2

nd

 Stage 1 cm

3

 - 700 bar 

maximum working pressure. 
 
HP212, HP232/D, HP252/D – Two Speed Manual 
Operation Aluminium Construction Pump – 
Displacement: 1

st

 Stage 12.9 cm

3 : 

2

nd

 Stage 2.3 

cm

3

 - 700 bar maximum working pressure 

 
HPX1500 – Two Speed Manual Operation Steel 
Construction Pump – Displacement: 1

st

 Stage 

20 cm

3 : 

2

nd

 Stage 1 cm

3

 - 1500 bar maximum 

working pressure 
 
HPX2800 – Two Speed Manual Operation Steel 
Construction Pump – Displacement: 1

st

 Stage 

20 cm

3 : 

2

nd

 Stage 0.8 cm

3

 - 2800 bar maximum 

working pressure 
 

4.0

 

Description:

 

HP110: 

1.

 

The pump may be used either horizontally 
or vertically with the hose end downwards. 
The pump is equipped with a pressure relief 
valve factory set at the maximum 
operating pressure. Before use unscrew 

transit plug and replace with breather on 
the top of the tank. This will maximise the oil 

volume available. See Figure 1.

 

 

 

 

2.

 

To advance the cylinder, turn the release 
knob clockwise. Operate pump handle.

  

See Figure 2

 

 

 

3.

 

Note: The cylinder will automatically be 
held in the advance position and will not 
retract of its own accord.   
 

4.

 

To retract the cylinder turn release knob 

anti-clockwise slowly, ensuring that the 
cylinder does not retract too fast as to 
make the operation unsafe. See Figure 3.

 

 

 

Reviews: