Installation Clearances
It is extremely important that you respect required installation distances and that you respect
local installation regulations. This is for your safety. The manufacturer is not responsible for the
product if it is not installed following these recommendations. These clearances may only be
reduced by means approved by the regulatory authority.
One necessary precaution when installing a wood stove is to leave sufficient space between the
stove (top, sides, back, front, and under stove pipes) and any other material that can catch fire.
The clearance from the top of the unit to the ceiling is 75" (1,905 mm). All other clearances are
found in the table below.
A combustible surface is anything that can burn (i.e. sheet rock, wall paper, wood, fabrics, etc.)
These surfaces are not limited to those that are visible and also include materials that are
behind non-combustible materials. If you are not sure of the combustible nature of a material,
consult your local fire officials.
Parallel Installation
Corner Installation
HF-517U
Single wall
connector pipe
A
– Chimney Connector to back wall
15.5” (394mm)
B
– Chimney Connector to sidewall
28” (711mm)
C
– Chimney Connector to corner wall
15” (381mm)
D
– Unit to back wall
13” (330mm)
E
– Unit to sidewall
20”(508mm)
F
– Unit to corner wall
7” (178mm)