IMPORTANT SAFETY INSTRUCTIONS 

Duration Per 

Day in Hours

8
6
4
3
2

1 ½

1

½

¼ or less

Sound Level dBA, 

slow response

90
92
95
97

100
102
105
110
115

WARNING:  When using electrical products, basic cautions should always be followed, including the following:

1. Read these instructions. 
2. Keep these instructions safe.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water. 
6. Clean only with a dry cloth.
7. Do not block any of the ventilation openings. Install in accordance with manufacturer’s instructions. 
8. Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including  
amplifiers) that produce heat.
9. An apparatus with Class I construction shall be connected to a mains socket outlet with a protective 
connection. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two 
blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The 
wide blade or third prong is provided for your safety. If the provided plug does not fit into your outlet, consult 
an electrician for replacement of the obsolete outlet. 
10. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and 
the point they exit from the apparatus.
11. Only use attachments/accessories provided by the manufacturer.
12. Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the 
apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from 
tip-over.
13. The mains plug or appliance coupler is used as the disconnect device and shall remain readily operable. The 
user should allow easy access to any mains plug, mains coupler and mains switch used in conjunction with this 
unit thus making it readily operable. Unplug this apparatus during lightning storms or when unused for long 
periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged 
in any way, such as when power-supply cord or plug is damaged, liquid has been spilled or objects have fallen 
into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been 
dropped.
15. Never break off the ground pin. Connect only to a power supply of the type marked on the unit adjacent to 
the power supply cord.
16. If this product is to be mounted in an equipment rack, rear support should be provided.
17. Note for UK only: If the colours of the wires in the mains lead of this unit do not correspond with the 
terminals in your plug‚ proceed as follows:
    a) The wire that is coloured green and yellow must be connected to the terminal that is marked by the letter 
E‚ the earth symbol‚ coloured green or coloured green and yellow.
    b) The wire that is coloured blue must be connected to the terminal that is marked with the letter N or the 
colour black.
    c) The wire that is coloured brown must be connected to the terminal that is marked with the letter L or 
the colour red.
18.This electrical apparatus should not be exposed to dripping or splashing and care should be taken not to 
place objects containing liquids, such as vases, upon the apparatus.
19. Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in 
susceptibility to noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently 
intense noise for a sufficient time.
    The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the following 
permissible noise level exposures: According to OSHA, any exposure in 
excess of the above permissible limits could result in some hearing loss. 
Earplugs or protectors to the ear canals or over the ears must be 
worn when operating this amplification system in order to prevent a 
permanent hearing loss, if exposure is in excess of the limits as set 
forth above. To ensure against potentially dangerous exposure to high 
sound pressure levels, it is recommended that all persons exposed to 
equipment capable of producing high sound pressure levels such as this 
amplification system be protected by hearing protectors while this unit 
is in operation.

Summary of Contents for TSM-10A

Page 1: ...ACTIVE STAGE MONITOR WWW HHELECTRONICS COM TSM 10A TSM 12A TSM 15A...

Page 2: ...herheitshinweise Deusch 5 Instrucciones Importantes Para Su Seguridad Espa ol 6 Important Safety Instructions Pt 2 7 Foreword 8 Introduction 9 TSM Front Panel 11 TSM Side Panel 12 TSM Setup Diagram 13...

Page 3: ...ratus has been damaged in any way such as when power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture...

Page 4: ...nne l assaut ou si inutilis pendant de longues p riodes 14 Seul un technicien agr par le fabriquant est m me de r parer contr ler votre unit Celle ci doit tre contr l e si elle a subit des dommages de...

Page 5: ...ttechnikern durchf hren Eine Wartung ist erforderlich wenn das Ger t in irgendeiner Art besch digt wurde etwa wenn das Netzkabel oder der Netzstecker besch digt wurden Fl ssigkeit oder Gegenst nde in...

Page 6: ...eren reparaciones cuando el aparato ha sido da ado de alguna manera como cuando el cable de alimentaci n o el enchufe se han da ado alg n l quido ha sido derramado o alg n objeto ha ca do dentro del a...

Page 7: ...user of the presence of important operating and maintenance Servicing instructions in the literature accompanying the product Dieses Symbol soll den Anwender vor unsolierten gefahrlichen Spannungen i...

Page 8: ...ur product as much as we enjoyed creating it By choosing HH you are joining a brand with heritage dating back to 1968 a brand that helped de ne the techniques and principles for sound reinforcement an...

Page 9: ...ability from your HH product Unpacking Inspect the product during unpacking if any damage is found notify the dealer you purchased it from immediately Be sure to save the carton and all packaging mate...

Page 10: ...on peaks in the music Using the monitor with this on all or much of the time will result in poor sound quality and damage to speakers and electronics 4 GRAPHIC EQUALISER A ve band graphic equaliser i...

Page 11: ...lume control is at minimum when switching on and off NOTE This product is convection cooled Do not cover the side panel Designed with Head Heart in the UK WWW HHELECTRONICS COM INPUT LINK OUT CAUTION...

Page 12: ...e input using a balanced or unbalanced XLR or a 6 3mm jack The input signal can be supplied to another device through a Male XLR in the Link TSM SERIES SETUP DIAGRAM TSM SERIES SETUP DIAGRAM Link Moni...

Page 13: ...length in gure 8 not loops Use electronic safety devices such as circuit breakers Start with EQ settings at and gains low Master volumes should be at zero for switch on and off Use the minimum cut or...

Page 14: ...0 HH HP 1044 12 HH HP 1250 15 HH HP 1550 Internal Speaker Impedance Internal X Over G W Kg 13Kg 15Kg 19Kg Measurement H W D mm H 316 W 400 D 455 H 341 W 431 D 500 H 378 W 490 D 563 2 way passive with...

Page 15: ...according to the recommendations of the WEEE Waste Electrical and Electronic Equipment directive applicable in your country In the interest of continued development HH Electronics reserves the right t...

Page 16: ......

Reviews: