Heyuan Intelligence DZS100-4P User Manual Download Page 4

 

                                                                                                                                                                                                         

Chapter 1 Meter Overview 

DZS100-4P  is  an  advanced,  smart  single-phase  DIN  rail  energy  meter.  It  meters  electric 
parameters  of  single-phase  current,  voltage,  power,  energy,  frequency,  power  factor  etc. 
with  high  accuracy.  It  is  LCD  display  and  also  equipped  with  RS485  communication  and 
pulse output. 
 
I

ts main functions are as follows:

 

 

Measure import active energy and export active energy; 

Measure combination of active energy, which is equal to the sum of import active energy 

and export active energy 

Measure  all  instantaneous  values  of  electric  parameters,  including  voltage,  current, 

power, energy, frequency, power factor etc.; 

LCD displaying voltage, current, power etc.. 

Automatically blocking and saving the blocked energy of last 12 months 

Timing Records with saving last 10 times of recording moments 

Loading  data  storage  with  recording  data  such  as  voltage,  current,  power,  frequency, 

power factor and active energy; 

Compatible with DL/T645-2007, DL/T645-1997 and Modbus-RTU protocols. 

 

Chapter 2 Specification & Technical Parameters 

2.1 Specification (the following parameters are subject to marks on nameplate) 

Reference Voltage: AC220V(Un) 
Current Specification: 1.5(6)A, 5(40) A, 10(80) A (which can be customized) 
Frequency: 50Hz 
Pulse Constant: 6400/1600/800imp/kWh (in the light of marks on nameplate)  
Accuracy Class: Class 1.0 

 

2.2 Technical Parameters 

Starting Current: 0.004Ib 
Insulation Strength: input to output, 2.0kV/min·1mA 
Power Consumption: 

2W,10VA 

Creeping:  Equipped  with  anti-creep  logic  circuits,  when  the  energy  meter  loads  115%  of 
rated voltage and there is no current in current circuit, the energy meter shouldn’t output 
more than one pulse in testing within the prescribed time. 
Voltage Range: 0.9

1.1Un; limit range: 0.8

1.2Un 

Communication Mode: RS485 
Reference Temperature: 23

℃±

2

;   

Reference Humidity: 40

%~

60

RH 

Working temperature: -20

~50

 

Storage Temperature:  -40

~70

  with  relative  humidity  less  than  85%  and  no  corrosive 

Summary of Contents for DZS100-4P

Page 1: ...DZS100 4P Single Phase Energy Meter User Manual Heyuan Intelligence Technology Co Ltd...

Page 2: ...ered to have read this manual and accept all our terms Heyuan shall not be responsible or liable for any damages or injuries caused by improper meter installation and or operation Attention the follow...

Page 3: ...2 Technical Parameters 1 Chapter 3 Dimension Wiring 2 3 1 Dimension 2 3 2 Terminals Wiring 2 Chapter 4 Communication Interface 3 Chapter 5 Meter Display Operation 3 5 1 Operation and Buttons 3 5 2 Dig...

Page 4: ...e current power frequency power factor and active energy Compatible with DL T645 2007 DL T645 1997 and Modbus RTU protocols Chapter 2 Specification Technical Parameters 2 1 Specification the following...

Page 5: ...ed 5 40 A 10 80 A wiring diagram directly connected Chapter 4 Communication Interface The meter is equipped with one communication interface The settable baud rates of RS485 communication are 1200bps...

Page 6: ...ted into hexadecimal whose last two digits are the Modbus communication protocol address For example if the bar code is 170510300920 the communication protocol address is 98 hexadecimal 152 decimal Ch...

Page 7: ...gure 1 LCD Display Interface Reference Diagram LCD Display Description LCD Display Description Password 3366 Import Energy High 6 digit for DL T645 Export Energy Low 6 digit for DL T645 Voltage Baud R...

Page 8: ...t according to actual situation will be charged Service Guarantee 1 Product technical consulting and quality complaints will be replied within 12 hours 2 Solutions for quality complaints will be provi...

Reviews: