Heyuan Intelligence DZ81-DZS310 User Manual Download Page 2

 

IMPORTANT DECLARATIONS 

 

Copyright © 2018 Heyuan Intelligence Technology Co., Ltd All Rights Reserved 
 
This manual may not be reproduced, copied, transmitted or transcribed in whole or in part by any means 
without the expressed written permission of Heyuan. Any shall be investigated for legal responsibility in 
violation of copyright or other intellectual property rights of the Company. We check the user manual’s 
contents regularly and will make necessary amendments in next version. Welcome to give advice for 
some unexpected errors. The rights of upgrading without notice are reserved. 
 
Please read this manual carefully before the product is operated. And once you start operating the meter, 
you’ll be considered to have read this manual and accept all our terms. Heyuan shall not be responsible 
or liable for any damages or injuries caused by improper meter installation and/or operation. 
 
Attention: the following symbols in this manual refer to meanings as follows 

   

Electric Shock Symbol: Carries information about procedures which must be followed to 

reduce the risk of electric shock and danger to personal health   

   

Safety Alert Symbol: Carries information about circumstances which if not considered may 

result in injury or death 
 

The meter must be installed and operated by one who has experience with high-voltage devices or has 
qualifications. Please connect the meter to correct voltage before operating the meter. Please install and 
use the meter according to the user manual. Heyuan shall not be responsible or liable for any damages 
or injuries caused without following the instructions in the user manual. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for DZ81-DZS310

Page 1: ...Smart Compact Din Rail Meter DZ81 DZS310 User Manual V1 0 Heyuan Intelligence Technology Co Ltd...

Page 2: ...ered to have read this manual and accept all our terms Heyuan shall not be responsible or liable for any damages or injuries caused by improper meter installation and or operation Attention the follow...

Page 3: ...2 3 2 Installation Method 2 Chapter 4 Terminals 2 Chapter 5 Typical Wiring 2 5 1 Three phase Four wire Wiring Mode under Low Voltage 2 5 2 Three phase Three wire Wiring Mode under Low Voltage 3 5 3 R...

Page 4: ...oltage Range 0 6Un 1 2Un 2 2 Input Current Secondary Current 100mA Measuring Range 1 In 4In 2 3 Energy Accuracy Class Class 1 Resolution 0 01kWh 2 4 Frequency Measurement Frequency Measuring Range 45...

Page 5: ...ion Environment DZS310 should be installed in a dry and dust free environment Avoid exposing meter to excessive heat radiation and high electrical noise sources Install Method DIN rail Mounting Chapte...

Page 6: ...3 A B C Ic Ia Ia Un Uc Ub Ua Ic Ib Ib N 5 2 Three phase Three wire Wiring Mode under Low Voltage A B C Ic Ia Ia Un Uc Ub Ua Ic Ib Ib 5 3 RS485 Interface 5 4 Interface of Energy Pulse Output PE PE...

Page 7: ...ero phase current Magnifying 1000 times 0 65535 4110 100E A phase active power Magnifying 1000 times 32768 32767 4111 100F B phase active power Magnifying 1000 times 32768 32767 4112 1010 C phase acti...

Page 8: ...83 1507 5384 1508 zero phase voltage Magnifying 100 times 0 4294967295 5385 1509 5386 150A line voltage A B Magnifying 100 times 0 4294967295 5387 150B 5388 150C line voltage B C Magnifying 100 times...

Page 9: ...r Magnifying 1000 times 2147483647 214748 3647 5417 1529 5418 152A total reactive power Magnifying 1000 times 2147483647 214748 3647 5419 152B 5420 152C A phase apparent power Magnifying 1000 times 0...

Page 10: ...2400 2 4800 3 9600 8196 2004 Wiring Mode 0 0 3LN 1 2LL 8197 2005 PT 1 1 9999 Remark 1 8198 2006 CT 1 1 9999 Remark 1 8199 2007 Energy Type Selection of Pulse Output 0 0 full wave active energy pulse...

Page 11: ...nents and freight shall be charged for improper meter installation and or operation 4 Over the warranty period part of the maintenance cost according to actual situation will be charged Service Guaran...