17
EN
(7) Fault finding
WARNING
:
Maintenance work shall have to be carried out with the unit switched off, i.e. with mains plug removed.
PROBLEM
CAUSE
Versio
n
SOLUTION
Motor is not operating
No power.
The unit has not been switched
on.
Impeller is blocked
Air inlet or outlet is blocked.
Switch has broken off.
Loose wiring.
B
B
B
B
HS
HS
Connect the unit; check the fuse.
Switch the unit on.
Remove the reason for the blockage.
Switch the unit off and let it cool down;
then remove blockage.
Order replacement switch from the dealer
or HEYLO.
Check wiring and tighten, if required.
The motor is running,
but the impeller turns
irregularly or makes
contact
A heavy impact has bent the
motor suspension so that the
impeller jams.
A heavy impact has caused the
motor to slip out of the
suspension so that the impeller
jams.
HS
HS
Remove the motor from the housing,
replace or repair the bent motor
suspension.
Remove the motor from the housing, then
place the motor in the suspension
correctly.
Unit vibrates
excessively
Collection of dirt on the wheel.
Unbalance of the impeller.
Impeller is bent.
Motor shaft is bent.
B
HS
HS
HS
Clean impeller.
Balance or replace the impeller.
Replace impeller.
Replace motor.
B = user HS = HEYLO service
Ask your local dealer for spare parts or get in touch with HEYLO service department.
(8) List of spare parts
Item
HEYLO Art. No.
Description
1
1761400
Fan wheel
2
1761401
Stator
3
1250212
Anti-static hose adapter
4
1761403
Fan grille
5
1761404
Housing
6
1761405
Motor
7
1761406
Hose canister holder
10
1761407
Rubber foot
11
1761408
Mains switch
14
1761413
Cable holder
17
1761402
Fastening screws
19
1761409
Motor flange
20
1761410
Mains switch button
22
1761412
Nut
23
1761415
Connection cable
24
1761414
Electronic housing
Summary of Contents for ComPact 1500 EX