Instruction for use • Switch unit AGS 80 D
Seite 14 von 29
Explanation:
For each alarm contact there is a relay with an operating and a rest contact.
−
G: common contact
−
A: operating contact
−
R: rest contact
When G is connected through to R, this means that an error has come up or that the equipment
has been switched off.
When G is connected through to A, this means that there is no error, i.e. the channel is OK.
5.4 Service Menu
The service menu is started by pressing the ENTER key. When no key has been activated in the
service menu for 1 minute it will be closed automatically.
The service menu is set up as follows:
1 Current messages
2 Old messages
3 I: Cyl. left II: Cyl. right
4 Info
5 Alarm thresholds
6 Service
7 EXIT
By using the UP and DOWN keys, the entry required can be selected (inverse presentation). By
pressing the ENTER key you can change to the corresponding sub-menu. You can leave the main
menu by selecting „7 EXIT“ and pressing the ENTER key. You can also leave the main menu by
pressing the QUIT key.