describes the LEDs on the nonport side of the switch.
Table 12 FCoE Converged Network Switch nonport side LED patterns
Recommended action
Status of hardware
LED color
LED name
Verify the power supply is on and
seated and the power cord is
Power supply is not receiving
power or is off.
No light
Power supply
status
connected to a functioning power
source.
No action required.
Power supply is operating
normally.
Steady green
Do the following:
Power supply is faulty.
NOTE:
When the switch is first
powered on, the power supply
status LED displays steady amber
until POST completes.
Steady amber (for
more than 5 seconds)
•
Check the power cable connection.
•
Verify that the power supply is
powered on.
•
Replace the power supply FRU.
Do the following:
Fan assembly is not receiving
power.
No light
Fan status
•
Verify the fan FRU is seated
correctly.
•
Verify the switch is powered on.
No action required.
Fan assembly is operating
normally.
Steady green
Do the following:
Fan fault for one of the following
reasons:
Steady amber (for
more than 5 seconds)
•
Verify the fan FRU is enabled (use
the
fanenable
command).
•
One or more of the fans in the
fan assembly has failed.
•
Replace the fan FRU.
•
The fan FRU has been
disabled.
NOTE:
When the switch is first
powered on, the fan status LED
displays steady amber until POST
completes.
Port side LED activity for the 1606 Extension SAN Switch
System activity and status can be determined through the activity of the LEDs on the 1606
Extension SAN Switch.
shows the LEDs on the port side of the 1606 Extension
SAN Switch.
The LED states are as follows:
•
No light
•
Steady light
•
Flashing light
The LEDs are either green or amber.
NOTE:
The LEDs may be solid amber or may flash during boot, POST, or other diagnostic
tests. This is normal; it does not indicate a problem unless the LEDs do not indicate a healthy
state after all boot processes and diagnostic tests are complete.