HEWI P.O. Box 1260 D-34442 Bad Arolsen

HEWI compact-wallreader ES5400 in combination with sub-
finery cover ES5410

Product description / scope

The HEWI compact-wallreader ES5400 is defined for usage within the electronic locking
system ES5000 to control peripheral devices like electric door openers, electric locks, electric
door and gate drives, elevators and so on.
The usage for scopes apart from the usual requests for electronic locking systems has to be
authorized by HEWI in the doubt. The wallreader ES5400 cannot be used for security-critical
applications and must not be used in humid rooms or outside of buildings. Please use the
variations ES5401, ES5402 and ES5403 for those applications. For further informations
contact the HEWI Servicecenter locking systems, fon +49 5691 82-200. The usage in dusty
environment without further protections (for instance the mountage in dust protected casings)
is not allowed.

Warning

a) Security against manipulation (unauthorized access)

Attention: If using the ES5400 manipulation in access-direction is possible, that means that
by removing the wallreader the connection cables can be used for operating the peripheral
device. For security-relevant applications the reader-module has to be seperated from the
basis-unit.

b) Environmental requirements

The protection-class corresponds to IP21, therefore the ES5400 has to be used inside of
buildings an in dry rooms. For the usage in humid rooms or in dusty environment, specially
designed products are offered.

c) Combination with peripheral devices

For the operation with peripheral devices the operating instructions, technical specifications
of the devices have to be observed.

d) Installation / maintenance

Installation and maintencae must be executed without power supply – danger of injury or
damage of the product or devices.

e) Sensitivity against contact (z.B. ESD)

Never touch electronical components or circuits of the circuit board, otherwise you could
damage the wallreader irreparable.

f) Combination with electrical door openers / special time zones

If a special time zone should be used, which operates an electrical door opener for a longer
time-period (> 20 s, e.g. opening from 9 to 12 am), you must use a door opener which could
endure permanent power.

g) Non-operating at blackout

During a blackout (no power-supply) the wallreader is non-operational. The wallreader has
an included battery-buffer, which guarantees the perservation of the stored data
(programming, internal clock) Nonetheless plase check the internal time after a longer
blackout. If a special time zone or a manual activated toggle-function was in work during the
blackout, it will be automatically deactivated for security reasons, even if it should be active in
the moment after the blackout. For example: A special time zone has been programmed
between 2 and 4 pm. During this time the relay is activated, a peripheral electrical door

Summary of Contents for ES5400

Page 1: ...ction class corresponds to IP21 therefore the ES5400 has to be used inside of buildings an in dry rooms For the usage in humid rooms or in dusty environment specially designed products are offered c C...

Page 2: ...wer of the wallreader and the peripheral devices Suitability of the wallreader for the environment especially the protection class IP21 The request at security of the system In doubt always use an add...

Page 3: ...d installation 1 Lock the wallreader in backside of the cover ES5410 Attention The LED should be in the upper left corner then the HEWI Logo is readable 2 Position of LED in the upper left corner Asse...

Page 4: ...e still connection cables into the right connector They fit automatically 4a De Installation Move the lever with a small screwdriver or smthg similar and remove the cable 5 Mount the wallreader onto t...

Page 5: ...malfunction or wrong programming This means especially alarm systems which are operated by the wallreader or locks in escape or outside doors Please control the event protocolls which can be evaluate...

Page 6: ...40 V AC DC 0 25 A Relay Opener NC Alarm max 40 V AC DC 0 25 A Connection cable I Y ST Y 8 x 2 x 0 8 Connectors EK 107 x 107 x 57 mm optional Power adaptor Depending on number of wallreaders Specific d...

Page 7: ...e the power supply has to be connected to input 1 outputs J2 1 closer 1 NO J2 2 closer 1 NO J2 3 opener 1 NC J2 4 opener 1 NC J2 5 opener 2 NC J2 6 opener 2 NC Serial interfaces J3 1 VCC onyl for sepe...