![Hettich Easys InnoTech Instructions On Installing Download Page 5](http://html1.mh-extra.com/html/hettich/easys-innotech/easys-innotech_instructions-on-installing_2127745005.webp)
Malfunction
Possible cause
What to do
Drawerorpull-outwillnotopen
Objectisobstructingdrawerorpull-out
Removeobject
Cabinetrunnerincorrectlypositioned
Positioncabinetrunnercorrectly
Drawerbackpaneldeformed
Straightendrawerbackpanel
Drawerorpull-outwillnotopen,insuficient
buffer travel
Gaptoosmall
Adjustgapalignment
Cabinetrunnerincorrectlypositioned
Positioncabinetrunnercorrectly
Nofrontpanelspaceritted
Fitfrontpanelspacer
Objectisobstructingdrawerorpull-out
Removeobject
Noneofeasysunitsittedrespondwhen
pushingorpullingondrawer
Unitplugconnectionfrompowersupplyunitto
plug-indistributorisnotpluggedinornotplugged
inproperly
Properlyconnectplugsatplug-indistributor
Connectingcablenotpluggedintoplug-in
distributororpluggedinproperly
Makesureplugconnectorisproperlyconnectedtodistributor
Individual easys units not working
Drawer not in easys sensing range
Correctlypositionsysteminfurniturecarcase
Easysnotpositionedcorrectlyonthepowerrail
Re-aligneasysonthepowerrail
Parallelactivationoftwounitsnotworking
Unit assignment incorrectly set
Setunitassignmentproperly(seepoint4)
Easysonlyrespondsafterpullingorpushing
several times
Systemisbeingoperatedtooquicklyinsuccession
Easysneedstorestforabout1.5secondsafterclosingthedrawer
Openingtravelinsuficientateasyssensor
Setfrontpanelspacing
GreenLEDnotlightinguponpowersupplyunit Plugnotinpowersocket
Makesuremainsplugispluggedinproperly
Unitplugnotpushedirmlyintopowersupplyunit
Makesureunitplugisproperlypluggedintopowersupplyunit
Powersocketswitchedoff
Switchpowersocketonatthepowersocketswitch
GreenLEDlashingonpowersupplyunit
System overloaded or short-circuited
Disconnectallunitsfrompowersupplyunitandstarttoconnect
eachunitindividually,checkingforproperworkingorder
LEDnotlightinguponautomaticdrive
Mainspowernotswitchedon
Switchonmainspower
Plugconnectionincorrectlyconnected
Checkplugconnection
Driveunitnotixedproperly
Setrotaryknobtocorrectpositionondriveunit(seepoint5)
LED flashing on automatic drive
Unit overloaded
Let unit cool down
No contact with data bus
Re-aligneasysonthepowerrail
Onopening,drawerorpull-outtravelsinto
limitationstopposition
Openingdistanceregulatorincorrectlysetondrive
unit
Adjustregulatorondriveunit(anti-clockwise)
Cabinetnotalignedhorizontally
Align cabinet horizontally
Severaldrawersorpull-outsopen
simultaneously
Fronts chafing against each other
Adjustgapalignment
Unit assignment incorrectly set
Setunitassignmentproperly(seepoint4)
Drawernotpushedopenfarenough
Openingdistanceregulatorincorrectlysetondrive
unit
Adjustregulatorondriveunit(clockwise)
Runnersystemstiff
Changedrawer
Drawerorpull-outnotclosingalltheway
Objectobstructingdrawerorpull-out
Removeobject
Driveunitnotpositionedcorrectly
Changedriveunit
Fronts chafing against each other
Adjustgapalignment
Driveunitnotpositionedcorrectly
Correctlypositiondriveunit
HFT-Nr.908434500
Subjecttotechnicalalterations.
Errorsandomissionsexcepted.
Malfunctions and possible causes