Hettich Easys ArciTech Installation Instructions Manual Download Page 1

Using these installation instructions 

Carefully read the safety precautions before commencing installa-
tion and starting the system.

Safety warning:

This warning sign indicates safety warnings that 
must always be followed.

Intended use

easys may only be installed and used under the following 
conditions: 

•  In dry rooms

• At temperatures ranging from 5 to 40°C

• I n conjunction with Quadro, InnoTech, ArciTech and Actro

drawer systems from Hettich

The manufacturer will not accept any liability for damage 
resulting from improper installation or failure to observe these 
installation instructions. 

Safety warnings

easys meets the level of safety requirements applicable at the 
time it was put onto the market. 

 

The system must only be installed, serviced, dismantled, put into
operation and adjusted by a properly trained person.

•  When installing easys, observe the standards and statutory

requirements applicable in your country.

•  Only connect the system to a power supply system that meets

the specifications shown on the rating plate on the power
supply unit.

•  The power socket must be readily accessible while carrying out

servicing and installation work. We recommend connecting the
power supply unit to a switched power socket.

 

Before commencing any cleaning or maintenance work, switch
the socket outlet off or disconnect the plug.

Make sure that no moisture is able to enter the power supply unit 
(danger to life). 

•  Only connect the power supply unit (provided) to the easys

system for which it is intended.

•  Never open the power supply unit or an automatic drive (danger

to life).

•  The maximum permissible cable length from the mains plug to

the furthest easys is 10 m, max. of 6 distributors.

• Do not use damaged parts.

• Sharp edges may lead to damage.

•  Other electrotechnical devices may interfere with the system

operation. If this occurs, contact the manufacturer or retailer of
the devices concerned.

 

To prevent drawers being operated unintentionally, we
recommend connecting the power supply unit to a socket outlet
with switch and turning the switch off as necessary

.

Modifications and replacement parts 

Never make modifications or use replacement parts not approved 
by the manufacturer as this will impair proper working order and 
safety.

• Only use genuine replacement parts.

•  It is only permissible for a properly trained person to change

components or make modifications to the wiring and power
supply.

Disposal

Dispose of your waste equipment at the collection point  
designated by your local authority for returning and recycling 
waste electrical and electronic equipment.

!

!

Störung

Ursache

Abhilfe

Schubkasten fährt beim Öffnen in den Anschlag

Korpus / Schubkasten nicht horizontal

ausgerichtetet

Korpus / Schubkasten horizontal ausrichten

Fehlende Leistungsreduzierung

Antriebseinheit bei geringen

Schubkastentiefen

Leistungsregler der Antriebseinheit reduzieren

Betriebsanzeige 

an einer Antriebs-

einheit geht alle 

10 Sekunden kurz aus

Antriebseinheit ist am Bus nicht angeschlossen Antriebseinheit vom Montageprofil 

demontieren und neu positionieren
Steckverbindungen prüfen und neu verbinden
Antriebseinheit austauschen

Mehrere Schubkästen öffnen gleichzeitig

Fronten streifen aneinander

Fugenbild einstellen

Gleiche Adresszuweisung für

unterschiedliche Antriebseinheiten /

Schubkastenebenen eingestellt

Jeder Antriebseinheit / Schubkastenebene nur

eine Adresse zuweisen

Schubkasten öffnet nicht weit genug

Korpus / Schubkasten nicht horizontal

ausgerichtetet

Korpus / Schubkasten horizontal ausrichten

Falsche Leistungseinstellung auf

Antriebseinheit

Leistungsregler der Antriebseinheit erhöhen

Schubkastenführung schwergängig

Schubkastenführung austauschen

Eine Antriebseinheit nicht ausreichend

zusätzliche Antriebseinheit einsetzen

Antriebseinheit defekt

Antriebseinheit austauschen

Unterschiedliche Adresszuweisung zwischen 

beiden Antriebseinheiten innerhalb einer 

Schubkastenebene

Beiden Antriebseinheiten einer 

Schubkastenebene gleiche Adresse zuweisen

Betriebsanzeige an einer 

Antriebseinheit geht alle 10 

Sekunden kurz aus

Antriebseinheit ist am Bus nicht angeschlossen Antriebseinheit vom Montageprofil 

demontieren und neu positionieren

Steckverbindungen prüfen und neu verbinden

Antriebseinheit austauschen

Betriebsanzeige an einer von 

beiden Antriebseinheiten 

innerhalb einer 

Schubkastenebene leuchtet nicht

Antriebseinheit defekt

Antriebseinheit austauschen

Betriebsanzeige an einer 

Antriebseinheit leuchtet 

nicht

Steckverbindungen zwischen Netzteil, 

Verteiler und unterer Montageprofilaufnahme 

unterbrochen

Steckverbindungen prüfen und neu verbinden

Antriebseinheit defekt

Antriebseinheit austauschen

Betriebsanzeigen an allen

Antriebseinheiten innerhalb

eines Korpus leuchten

nicht. Netzteil leuchtet

Steckverbindungen zwischen Netzteil,

Verteiler oder unterer

Montageprofilaufnahme unterbrochen

Steckverbindungen prüfen und neu verbinden

Verbindungsleitungen defekt

Verbindungsleitungen austauschen

Verteiler defekt

Verteiler austauschen

Untere Montageprofilaufnahme defekt

Untere Montageprofilaufnahme

austauschen

Betriebsanzeige an einer von beiden

Antriebseinheiten innerhalb einer

Schubkastenebene blinkt

Antriebseinheit vom Montageprofil 

demontieren und neu positionieren

Betriebsanzeige an einer von beiden

Antriebseinheiten innerhalb einer

Schubkastenebene leuchtet nicht

Antriebseinheit austauschen

Unterschiedliche Adresszuweisung

zwischen beiden Antriebseinheiten

innerhalb einer Schubkastenebene

Beiden Antriebseinheiten einer

Schubkastenebene gleiche Adresse zuweisen

Schubkasten schließt nicht vollständig

Gegenstand blockiert den Schubkasten

Gegenstand entfernen

Fronten streifen aneinander

Fugenbild einstellen

Hebel Antriebseinheit nicht

zurückgefahren

Folgende Schritte durchführen:

1. Hebel Antriebseinheit manuell

zurückfahren

2. Netzteil ausschalten. Nach 5 s wieder

einschalten.

3. Falls sich Fehler wiederholt

Antriebseinheit austauschen

Position des Schubkastens bzw. Tiefen- / 

Höhenposition der Antriebseinheit falsch

Position des Schubkastens bzw. Tiefen- / 

Höhenposition der Antriebseinheit anpassen

Technik für Möbel

Hettich Marketing- und Vertriebs GmbH & Co. KG · Vahrenkampstraße 12 -16 · 32278 Kirchlengern · T 49 52 23/77-0 · www.hettich.com

Hettich Marketing- und Vertriebs GmbH & Co. KG · Vahrenkampstraße 12 -16 · 32278 Kirchlengern · T 49 52 23/77-0 · www.hettich.com

5

Easys

 - ArciTech / InnoTech

Using these installation instructions 

Summary of Contents for Easys ArciTech

Page 1: ...socket outlet off or disconnect the plug Make sure that no moisture is able to enter the power supply unit danger to life Only connect the power supply unit provided to the easys system for which it...

Page 2: ...carcase Power supply unit lit Break in connections between power supply unit distributor or lower mounting profile retainer Check connections and re connect Connecting cables faulty Change connecting...

Page 3: ...d re position Check connections and re connect Change drive unit Power indicator not lit on one of the two drive units within a drawer level Drive unit faulty Change drive unit Power indicator not lit...

Page 4: ...Marketing und Vertriebs GmbH Co KG Vahrenkampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 www hettich com easys 5 40 InnoTech Quadro ArciTech Actro Hettich easys easys easys easys easys 10 6...

Page 5: ...Hettich Marketing und Vertriebs GmbH Co KG Vahrenkampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 www hettich com 24 2x 300 4 1 5 0 5...

Page 6: ...Technik f r M bel Hettich Marketing und Vertriebs GmbH Co KG Vahrenkampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 www hettich com 25 3 4 5 6 2 1 3 4 5 6 2 1 3 5x20 3 5x20 10 10 1 2 5 3...

Page 7: ...s GmbH Co KG Vahrenkampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 www hettich com 32 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2...

Page 8: ...s im ausgesch alteten Zustand den Vorteil dass kleine Kinder das System nicht spielerisc h nutzen k nnen und dass in Ihrer Abwesen heit Urlaub ein unn tige r Standby Stromver brauch vermiede n wird MO...

Page 9: ...X H Y 7 X Y NL 270 300 350 400 450 500 550 600 650 700 X 251 281 331 381 431 481 531 581 631 681 Y min 291 321 371 421 471 521 571 621 671 721 NL NL NL NL NL NL NL 270 300 350 400 450 500 550 600 650...

Page 10: ...ng und Vertriebs GmbH Co KG Vahrenkampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 www hettich com 35 GLUE 4 Technik f r M bel 3 5 x 25 NL NL NL 7 X Y NL NL NL NL 7 X Y NL 7 X Y NL 3 5 x 25 N...

Page 11: ...Pos 2 Pos 1 19 19 3 4 5 6 2 1 3 4 5 6 2 1 3 4 5 6 2 1 6 1 2 3 4 5 6 ma x mi n 3 1 2 1 2 3 4 5 6 max min 1 2 3 4 5 6 ma x mi n 3 5b 49 14 9 12 32 10 5 1 5 4 5 3 16 6 3 16 16 1 5 4 5 49 14 12 12 32 10...

Page 12: ...n A B C B 4 4 4 6 3 IN 24 VDC OUT 24 VDC D E 4 4 4 6 3 IN 24 VDC OUT 24 VDC C A 4 4 4 6 3 IN 24 VDC OUT 24 VDC 2 x 3 5 x 13 mm 2 x 3 5 x 13 mm 4 5 6 3 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 D E 1 2 3 4 5 6 max...

Page 13: ...3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min A B B 4 4 4 IN 24 VDC D E 4 4 4 IN 24 VDC C A 1 6 5 4 3 2 max 10 m 1 1 1 1 1 2 3 4 5...

Page 14: ...M bel Hettich Marketing und Vertriebs GmbH Co KG Vahrenkampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 www hettich com 39 1 2 3 4 5 6 max min max min max min 1 2 3 4 5 6 max min 1 2 3 4 5 6...

Page 15: ...kampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 Internet www hettich com 1 5 6 m a x m i n m a x m i n m a x m i n 40 Easys InnoTech Hettich Marketing und Vertriebs GmbH Co KG Vahrenkampstra...

Page 16: ...r Abwesen heit Urlaub ein unn tige r Standby Stromver brauch vermiede n wird MO 00124 00 000 3 Beschreibu ng 3 1 Bauteile Montageprof il Montageprof ilaufnahme oben Montageprof ilaufnahme unten automa...

Page 17: ...X H Y 7 X Y A mm 260 300 350 420 470 520 620 X 250 290 340 410 460 510 610 Y min 290 330 380 450 500 550 650 A A A A A A A A mm 260 300 350 420 470 520 620 X 265 305 355 425 475 525 625 Y min 305 345...

Page 18: ...ertiebs GmbH Co KG Vahrenkampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 www hettich com 43 8 8 12 B B 2 300 mm 8 8 12 20 B B 2 20 300 mm 4x 2x GLUE i 1 2 3 4 5 6 max min NL A Y 1 2 3 4 5 6...

Page 19: ...6 2 1 3 4 5 6 2 1 3 4 5 6 2 1 min 72 min 37 min 5 min 5 min 5 min 8 Pos 3 Pos 2 Pos 1 5 1 2 3 4 5 6 ma x mi n 3 1 2 1 2 3 4 5 6 max min 1 2 3 4 5 6 ma x mi n 3 4b 49 14 9 12 32 10 5 1 5 4 5 3 16 6 3 1...

Page 20: ...n 1 2 3 4 5 6 max min A B A B 4 4 4 6 3 IN 24 VDC OUT 24 VDC 4 4 4 6 3 IN 24 VDC OUT 24 VDC 2 x 3 5 x 13 mm 2 x 3 5 x 13 mm 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max...

Page 21: ...4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min A B B 4 4 4 IN 24 VDC D E 4 4 4 IN 24 VDC C A 1 6 5 4 3 2 max 10 m 1 1 1 1 1 2 3 4 5...

Page 22: ...Marketing und Vertiebs GmbH Co KG Vahrenkampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 www hettich com 47 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min max min max min Technik...

Page 23: ...Y 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min X Y X Y X Y min X Y 7 7 X Y 134 176 20 7 66 X 4 91 7 X min 16 Y 7 7 X Y 91 38 91 8 24 7 X 176 20 7 66 X 4 91 7 X min 16 4 x 3 5 x 20 mm I...

Page 24: ...nkampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 www hettich com 3 1 2 1 2 3 4 5 6 max min 1 2 3 4 5 6 ma x mi n 3 4a 37 57 132 5 20 Actro Quadro 56 19 91 8 176 20 7 66 X 7 X 4 x 3 5 x 20 mm...

Page 25: ...C OUT 24 VDC A 4 4 4 6 3 IN 24 VD C OUT 24 VD C 2 x 3 5 x 13 mm Technik f r M bel Hettich Marketing und Vertriebs GmbH Co KG Vahrenkampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 www hettich...

Page 26: ...max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min 1 2 3 4 5 6 max min ma min A B C 5 20 37 52 132 200 200 3 4 5 6 2 1 3 4 5 6 2 1 37 min 8 min 5 min 5 min 72 Actro Quadro 56 19 C A B 4 4 4 6 3 IN 24 VD...

Page 27: ...electric shock Never open a faulty power supply unit or a faulty drive Danger to life Immediately instruct an authorised electrician to rectify damage to the cabling Be aware that electrical devices h...

Page 28: ...ectrically The drawer is moved forward by an ejection lever in response to a push or pull on the front panel The system is only activated by a short push or pull It will not open in response to a prol...

Page 29: ...ator not lit on any of the drive units No power at socket outlet Check fuse switched socket outlet If necessary consult a qualified electrician Notify retailer fitter Drawer only opens after pulling o...

Page 30: ...Easys 5 40 Quadro InnoTech ComfortLine ArciTech Hettich 2 Easys 2 1 Easys 2 2 Hettich Marketing und Vertriebs GmbH Co KG Vahrenkampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 www hettich com...

Page 31: ...h Marketing und Vertriebs GmbH Co KG Vahrenkampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 www hettich com 23 2 3 2 4 a 100 240 V 50 60 Hz b 24 V DC SELV c 90 W d II Easys e III f 4 A 3 Easy...

Page 32: ...6 Hettich Marketing und Vertriebs GmbH Co KG Vahrenkampstra e 12 16 32278 Kirchlengern Telefon 49 52 23 77 0 www hettich com 1 5 2x 24...

Reviews: