background image

When connection external air flow use a ø100 
air conduit   (for instance Lindab) with match-
ing collar band.

Connection of external air flow (fresh air) 
through the floor on Scan-Line 805 Aqua

The stove is prepared 
for a fresh air intake. 

Summary of Contents for SCAN-LINE 805 AQUA

Page 1: ...ERATING AND INSTALLATION INSTRUCTIONS DANISH DESIGN DANISH QUALITY DANISH PRODUCTION www heta dk EN SCAN LINE 805 AQUA Approved for use in smoke control areas when burning dry wood logs or authorised fuels ...

Page 2: ...CO emission i mg Nm3 960 mg Nm3 Middel CO emission 0 077 Røggas temperatur 204o C Støv 10 mg Nm3 Virkningsgrad 86 NOx 80 mg Nm3 OGC 76 mgC Nm3 DOP Scan Line 1000 2017 8057 0000 DK Congratulations on your new wood stove insert we are confident that you will be more than satis fied with your new Heta stove Especially if you follow the following advice and instructions Scan Line 805 Aqua is approved ...

Page 3: ...ollow national and local regulations However the area of the ope ning should never be less than 175 cm2 which corresponds to a diameter of 150 mm If a dam per is fitted in the flue gas pipe there must al ways be at least 20 cm2 of free passage even when the damper is in its closed position Wood burning stoves must never be con nected to chimneys that are also linked to a gasfired heater An efficie...

Page 4: ...d wood or chipboard as these materials can emit poisonous fumes and smoke Correct fi ring using well seasoned wood provides opti mal heat output and maximum economy At the same time correct firing prevents environmental damage in the form of smoke and emmissions and also reduces the risk of chimney fires If the wood is wet and inadequately seasoned a large proportion of the energy in the fuel will...

Page 5: ...ight the fuel The flames must work from the top down The use of lighter fluid oils or any liquid fuels is strictly forbid den from use in a wood stove Fully open the combustion air and leave the door ajar about 1 cm open Once the fire is established and the chimney is hot after about 3 5 minutes closed door and regulate the air into operating position We re commend all of the first fuel is burned ...

Page 6: ... will become covered with soot If this situation is combined with firing with wet wood the build up of soot can become so thick and sticky that the sealing rope can for example become detached when the door is opened the next day Risk of explosion After you add new fuel it is very important that you do not leave the stove unattended until the wood is burning constantly This will normally occur wit...

Page 7: ...m 550 sq mm under Building Regulations if the stove is not going to be fitted to an external outside fresh air supply Houses built after 2008 where the air leakage rate is less than than 5 m3 hour m2 then a ventilator equiva lent to 550 mm2 per kW output will be required 9kW x 550 mm 4950 mm2 Guarantee Heta wood stoves subjected to a strict quality control during production and before delivery to ...

Page 8: ...on external air flow use a ø100 air conduit for instance Lindab with match ing collar band Connection of external air flow fresh air through the floor on Scan Line 805 Aqua The stove is prepared for a fresh air intake ...

Page 9: ...when you receive it from Heta otherwise it will result in great loss of efficiency and raise the temperature of the chimney Tip the top plate so that possible soot can fall down into the cumbustion chamber afterwards it is very important that the plate is put back in place as it otherwise will result in great loss of efficiency and raise the temperature of the chimney 2 3 4 5 ...

Page 10: ...10 Cleaning after sweeping the chimney and replacing the stones Scan Line 805 Aqua 1 7 6 5 4 3 2 ...

Page 11: ...ur and that the existing system has a safety valve which opens by maximum 4 bar overpressure The SYR valve point 5 is an extra safety de vice which opens by a temperature over 95 in the boiler Connect cold water pressure on maximum 15 on the water connection point 1 make sure that your water company supplies approx 600 litres per hour This could be checked by seeing if you can fill a 10 litres buc...

Page 12: ...12 ...

Reviews: