Connection water to Scan-Line 805 Aqua
Automatic ventilator
Forward motion (warm)
1/2” RG (point 4)
12 mm copper pipe for
water connection
(point 1)
12 mm copper pipe for
water for outlet
- boiling safety fuse
(point 2)
Return (cold) 1/2”
RG (point 3)
SYR-Temperature valve
(pkt. 5)
Scan-Line 805 Aqua is delivered from Heta so
that it can be fitted on an existing system with
matching circulating pump and safety valve.
By connection you should make sure that the
stove is supplied minimum 140 litres of water
per hour and that the existing system has a
safety valve which opens by maximum 4 bar
overpressure.
The SYR valve (point 5) is an extra safety de-
vice which opens by a temperature over 95° in
the boiler.
Connect cold water pressure on maximum 15°
on the ½” water connection (point 1) (make
sure that your water company supplies approx.
600 litres per hour. This could be checked by
seeing if you can fill a 10 litres bucket on 1
minute.).
Connect the 12 mm copper pipe for (point 2)
water for outlet to the existing outlet so that
you visually can see if the extra safety device
has been activated.
NB!! The installation should always
be carried out in accordance with
valid standards and regulations by
an authorized electrician.
Summary of Contents for SCAN-LINE 805 AQUA