BACK VENTING
When venting out through the wall, one or two elbows are required, depending on the blower
configuration:
ELBOW FOR 600 CFM
Units (hoods/liners) with 600 CFM blower systems require one 8” elbow for the blower unit
ELBOWS FOR 900 CFM
Units with 900 CFM blower systems require one 8” elbow and one 6” elbow
ELBOWS FOR 1200 CFM
Units with 1200 CFM blower systems require two 8” elbows, one for each 600 CFM blower unit.
Standard 6” [15.2 cm] round - 8-1/2” [21.6 cm]
Standard 8” [20.3 cm] round - 10-3/4” [27.3 cm]
Elbow and Transition Heights
600 CFM fan module uses 8” round
300 CFM fan module uses 6” round
(Drawing Not To Scale)
Side View
8” Round
Height when
fully adjusted to
90 degrees:
H
12”
[30.5 cm]
6”
[15.2 cm]
16”
[40.6 cm]
8” Round
[20.3 cm]
8-1/2”
[21.6 cm]
Hood Enclosure
(supplied by customer)
Low profile elbow: 8” to 6” x 8-1/2”
Hestan P/N AKVBE8
INSTALLATION
(CONT.)
©2019 Hestan Commercial Corporation
15
EN