HUCO Series 

Assembly, Double Oven  

1)

 

If legs will be used, assemble provided legs to bottom oven.  

2)

 

If casters will be used: 

a.

 

Install locking casters to front of bottom oven 

b.

 

Install non-locking casters to rear of bottom oven  

3)

 

Ensure casters will not roll, then set top oven on bottom oven, 

4)

 

Secure units to each other at rear with two ¼-20 nuts and bolts on each side, as shown in the figure. 

5)

 

For units that are already stacked, follow steps 1 and 2. 

Caster installation notes 

If casters are provided, match holes on the caster with holes on the oven bottom base or extended legs stand and 
fasten with bolts provided. NOTE: Locking type casters mount on the front side of oven. 

Leveling:  

A carpenter’s spirit level should be placed on the oven’s center baking rack and the unit leveled both front-to-back 
and side-to- side. If it is not level, cakes, casseroles, and any other liquid or semi-liquid batter will not bake evenly, 
burner combustion may be erratic, and the unit will not function efficiently. 
If the floor is relatively smooth and level, the unit may be further leveled with adjustment in the foot of the leg. 
Units with casters must be leveled with shims. A unit will probably not return to the same position after being 
moved, requiring re-leveling after each and every move. 
 

Statutory Regulations

 

(Install Codes) 

The installation of this appliance must be carried out by a properly trained and qualified installer and in accordance 
with the relevant regulations, codes of practice and the related publications of the Country, State, County and City of 
destination. 

United States of America

 

Installation must conform with local codes, or in the absence of local codes, with the 

National

 

Fuel Gas Code, ANSI 

Z-223.1 

(latest edition.).  

Electrical wiring from the electric meter, main control box or service outlet to appliance must be electrically 
grounded in accordance with local codes or in the absence of local codes, with  

National Electrical Codes ANSI/NFPA 

70 

– current 

Canada 

Installation must conform to installation codes for gas burning appliances and equipment standard 

CAN1-B149.1 

(Natural. gas) or 

CAN1-B149.2 

(Propane gas). 

Electrical wiring from the Electric Meter, main control box or service outlet to appliance must be electrically 
grounded in accordance with local codes or in the absence of local codes,  in Canada, conform to Canadian 

Electrical 

Code CSA-C22.1

 

Resources 

American Gas Association, Inc.: http://www.aga.org/ 
National Fire Protection Association: http://www.nfpa.org/ 

CSA: http://www.csa.ca  
 

 

Summary of Contents for HUCO Series

Page 1: ......

Page 2: ...T THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER IN...

Page 3: ...uirement 6 Gas Supply 6 Gas Supply Notes 6 Flexible Coupling Connectors and Casters 6 Gas Pressure Regulator 7 Factory Adjusted System 7 Checking for Leaks 7 Air Supply Ventilation 8 Electrical Connec...

Page 4: ...learance must be maintained so that the combustion and ventilation air is not obstructed for proper operation The oven must not be mounted on a curb base It must be mounted on the casters or legs prov...

Page 5: ...t be leveled with shims A unit will probably not return to the same position after being moved requiring re leveling after each and every move Statutory Regulations Install Codes The installation of t...

Page 6: ...l Serial Rating Plate Locations on page 8 Connect a unit stamped NAT only to natural gas and stamped LP only to propane gas 2 If it is a new installation have the gas authorities check the meter size...

Page 7: ...specified on the rating plate The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system where pressures are in ex...

Page 8: ...e overall air conditioning system can produce a slight vacuum in the room and or cause air drafts either of which can interfere with pilot or burner performance and can also be hard to diagnose Air mo...

Page 9: ...urner should light 4 Check the burner orifice elbow connection downstream of the valve with a soapy water solution 5 Check the burner visually for blue flame See the figure below for proper flame appe...

Page 10: ...ables burner Doors can be opened and fan will stay on for cool down TIMER control For cooking convenience sounds an alert when time finishes Alert only does not affect oven operation Normal Use 1 Plac...

Page 11: ...n hour Place the switch to the COOL position and open the door When oven temperature is equal to room temperature turn unit off Periodic Cleaning Check the ventilation system periodically to see that...

Page 12: ...2018 Hestan Commercial 12 HUCO Series Hestan Commercial Products 888 905 7463...

Reviews: