hestan HUCO Series Owner'S Manual Download Page 2

©2018 Hestan Commercial 

2

  

HUCO Series 

 

IMPORTANT FOR YOUR SAFETY  

 

THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL 

GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND 

ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. 

 
 

POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN 

THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE 

OBTAINED FROM THE LOCAL GAS SUPPLIER. 

 
 

IMPORTANT  

 

IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN 

SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER 

FOR SERVICE. 

 

FOR YOUR SAFETY 

 

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR 

LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. 

 
 

WARNING 

 

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR 

MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ 

THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS 

THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT. 

 

IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS 

DEVICE. 

 

 

CALIFORNIA PROPOSITION 65 - WARNING 

WARNING

  This product can expose you to chemicals including carbon monoxide, which is known to the 

State of California to cause cancer. 
For more information, go to 

www.P65Warnings.ca.gov

 
 

Summary of Contents for HUCO Series

Page 1: ......

Page 2: ...T THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER IN...

Page 3: ...uirement 6 Gas Supply 6 Gas Supply Notes 6 Flexible Coupling Connectors and Casters 6 Gas Pressure Regulator 7 Factory Adjusted System 7 Checking for Leaks 7 Air Supply Ventilation 8 Electrical Connec...

Page 4: ...learance must be maintained so that the combustion and ventilation air is not obstructed for proper operation The oven must not be mounted on a curb base It must be mounted on the casters or legs prov...

Page 5: ...t be leveled with shims A unit will probably not return to the same position after being moved requiring re leveling after each and every move Statutory Regulations Install Codes The installation of t...

Page 6: ...l Serial Rating Plate Locations on page 8 Connect a unit stamped NAT only to natural gas and stamped LP only to propane gas 2 If it is a new installation have the gas authorities check the meter size...

Page 7: ...specified on the rating plate The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system where pressures are in ex...

Page 8: ...e overall air conditioning system can produce a slight vacuum in the room and or cause air drafts either of which can interfere with pilot or burner performance and can also be hard to diagnose Air mo...

Page 9: ...urner should light 4 Check the burner orifice elbow connection downstream of the valve with a soapy water solution 5 Check the burner visually for blue flame See the figure below for proper flame appe...

Page 10: ...ables burner Doors can be opened and fan will stay on for cool down TIMER control For cooking convenience sounds an alert when time finishes Alert only does not affect oven operation Normal Use 1 Plac...

Page 11: ...n hour Place the switch to the COOL position and open the door When oven temperature is equal to room temperature turn unit off Periodic Cleaning Check the ventilation system periodically to see that...

Page 12: ...2018 Hestan Commercial 12 HUCO Series Hestan Commercial Products 888 905 7463...