Technical data

Installation

Lighting variants

 

Depending on the lighting job in hand, LED kit 
variants are available where the light is emitted 
symmetrically or asymmetrically. If using the 
asymmetric variants, please note the dot marks 
for correctly aligning to the street side. 

100%

dim

aus

T

dim

Level

ein

T

dim

AutomaticDimControl (ADC) setting

 

 
The LED kit is equipped with an OSRAM Optotronic4DIM 
LED operating device or similar from Philips, for exam-
ple, to suit your project.

In this case, parameters for the dimming functionality 
and dimming profile are set in the factory by means of 
software programming as requested by the customer. 
In order to set parameters for the AstroDIM function 
(automatic dimming, based on midnight), the Tdimein 
and Tdimaus values desired for the system and the 
desired level of dimming (50% is standard) should be 
communicated with the order. The values set in the 
factory are shown on a sticker located next to the type 
plate. The parameter settings can only be changed 
using a specific programming adapter and a PC with 
the corresponding programming software.

Using the PSt input, the LED kit can be added to an 
existing control phase. If this is done, the existing con-
trol logic is detected automatically once switched on 
for around 20min.

•  (1)

 Open the luminaire canopy and remove the exist-

ing device carrier. 

•  For luminaires with a newer date of manufacture, 

the device carrier is attached to the hinge with two 
screws 

(S)

. With older ones, it is inserted. 

•  Fix the LED luminaire head unit to the hinge with the 

two screws 

(S)

 in the case of newer luminaires, or 

use the swing-out support wings 

(AF)

 to place it on 

the hexagonal frame in the case of older luminaires. 
Make sure that the recess for the cable gland 

(KD)

 is 

in the correct position.   

•  (2)

 In the case of an LED kit with asymmetrical light 

distribution, align the light unit 

(LE)

 in the correct 

beam direction by rotating it. Observe the dot mark-
ing 

(4)

 on the light outlet element. 

•  (3)

 Connect the LED recessed luminaire head (LK); if 

necessary, install the device plug. 
 

Note: for more information about the device plug, 

see back page.

 

 
Close the luminaire canopy again, then connect the 
luminaire to the mains and check its function. 

•  Mark upgrade on LED, if necessary in the luminaire/

on the pole. Keep assembly instructions for mainte-
nance at a later date. 

•  Correctly dispose of removed materials/compo-

nents. 
 
 

Note

If mains are frequently subject to peaks in voltage, 
take additional relevant surge protection measures 
as necessary. 

Elect. connection

0.3m connection cable 

3x0.75mm²

Dimensions

Ø 537/H175

Weight

1400g

Ingress protection

IP20 

IP54 (from below)

Ingress protection of luminaire

≥ IP43

Ambient temperature

-35....+35°C

Volume of lamp space

≥ 14dm³

Nominal voltage

220-240V AC 50Hz 

2)

Power factor

> 0.9

Protection rating

II

Overvoltage protection

6KV (surge)

Nominal power [W]

Asym

Sym

HIGHPOWER

23-28

32-36

PROFESSIONAL 

16-19

24-28

BASIC

16

24

Luminous flux with directional 

optics [klm]

Asym

Sym

HIGHPOWER

2.5 

constant

3.5 

constant

PROFESSIONAL

1.8 

constant

2.5 

constant

BASIC

1.8

2.5

Colour rendering index (CRI)

> 80

Conformity

CE

Special equipment 

TempSafe (TS) 

overtemperature protection

 

Constant Flux (CF) 

constant luminous flux over 50,000hr

 

AutomaticDimControl (ADC) 

1) 

LED kit is basically suitable for use in systems where dimming 

is controlled by reducing voltage and/or varying frequency and 

works independently of the voltage/frequency conditions with 

a constant light output. We would recommend investigating 

suitability for use on a case-by-case basis.

Please note details on the type plate!