![HESCH HE 5411 Operating Instructions Manual Download Page 11](http://html1.mh-extra.com/html/hesch/he-5411/he-5411_operating-instructions-manual_2127274011.webp)
HE 5411 Operating Instructions
#340411 | version 1.7
11
Housing
Type
Dust-tight polycarbonate housing
Dimensions
113 × 80 × 60 (W × H × D)
113 × 110 × 60 (W × H × D) incl. connection
coupling
Protection type
IP 65
Mounting
Wall-mounted, vertical mounting position
Cable gland
1 × M20 × 1,5 N (for cable diameters 6-12 mm)
with multiple sealing insert for 2 x cables Ø 6
mm
Identification
Device identification/explosion protection
See chapter 2.4 Device Identification
Climatic environmental conditions
Storage
-
20°…+60° C
Transport
-
20°…+85° C
Operation
-
20°…+55° C
In EX zone: -
20 °C…+40 °C
Relative air humidity
75% rel. humidity, no condensation
Air and creepage distances
Pollution degree
2
Overvoltage category
II
Material group
IIIa
Rated voltage
<
150 V AC, ≤ 250 V AC
Test voltage (basic insulation):
1250 V AC, 1 min
Test voltage (added insulation):
3000 V AC, 1 min
Power connection
Connection type
Push-in-spring connection
Wire size
0.2 mm²…1.5 mm²
Flexible wire size
0.2 mm²…1.5 mm²
AWG wire size / kcmil
24…16
Flexible wire size with ferrule without
plastic sleeve
0.2 mm²…1.5 mm²
Flexible wire size with ferrule with plastic
sleeve
0
.2 mm²…0.75 mm²
Extras
Special characteristics
Free from silicone
1
1
Silicone is not used in the production process.