HESA HE400 Technical Documentation Manual Download Page 8

Model HE400 mi cro wa ve barrier

DT01142 - Page 8

DOCU MEN TAZI ONE TEC NICA

TECH NI CAL DOCU MEN TA TION

Min.

Norm.

Max.

Note

Wor king fre quency

9.5 GHz

9.9 GHz

9.95 GHz

Ma xi mum power

3 mW

Mo du la tion

On/off

Du ty-cyc le

50/50

Number of chan nels

4

Ge ne ral in ter nal re fe ren ce vol ta ge

13.8 VDC

RX cur rent drain in stand-by mode

45 mA

RX cur rent drain in alarm con dition

40 mA

TX cur rent drain

38 mA

ALARM OUT PUTS

TX tam per, ope ning and mo vement (NC)

30 VA

P max

RX tam per, ope ning and mo vement (NC)

30 VA

P max

RX alarm out put (NC)

100 mA

I max

CON TROL

RX sen si ti vity

Trim mer

The fol lowing sta tement will be pro vided with the equi pent as re quired by Ar ticle 6.3 of the R&TTE Di rective, 199/05/EC:

HE400T

 is in con formity with all es sential re quirements of the R&TTE Directive 1999/05/EC. This equi pement has been as sessed to the fol lowing stan dards:

• Draft ETSI EN 300 440 part 1&2, July 2000 
• ETS 300 683: June 1997
• EN 60950: 1992, Incl Amdt 1.4, 11 (+EN 41003/1993)
This pro duct is mar ked with 

    0682

wich si gni fies con for mity with Class II pro duct re qui re ments spe ci fied in the R&TTE Di rec ti ve.

Hesa S.p.a. also declare the pro duct

HE400

, is in con formity with 89/336/EEC and 73/23/EEC di rectives .

The pro duct. HE400 has been as sessed to the fol lowing stan dards:
• ETS 300 683: June 1997
• EN 60950: 1992, Incl Amdt 1.4, 11 (+EN 41003/1993)

!

TECH NI CAL SPECI FI CA TIONS

Summary of Contents for HE400

Page 1: ...ssed so that it causes an alarm re lay to be energized When an intruder approaches the beam the energy detected by the receiver causes if the predetermined level is reached the relay to be de energize...

Page 2: ...overlapping of two barriers that are crossing or that are installed in parallel Plea se note that the uncovered area increases by decrea sing the sensitivity see Figure 4 Typically the height should b...

Page 3: ...Model HE400 microwave barrier DT01142 Page 3 DOCUMENTAZIONE TECNICA TECHNICAL DOCUMENTATION Fig 4 Installation height of devices Fig 3 Attention to dead zones...

Page 4: ...r parking guards may be used to protect equipment from damage from vehicles see Figure 7 Best security Choose the location that will provide best security yet be free from nuisance alarms Al ways loca...

Page 5: ...tput N C for protection against unauthorized openings movements or tampe ring In normal conditions there is a NC circuit 0 ohm voltage free The opening of the contact is determined by a movement of th...

Page 6: ...t of the trasformer PT0 PT1 tamper circuit output N C for protection against unauthorized openings movements or tampe ring In normal conditions there is a NC circuit 0 ohm voltage free The opening of...

Page 7: ...X speed detection turn clockwise to lower this parameter and on the op posite for increasing it see on the printed circuit for re ference signals PT5 Trimmer for adjusting the RX sensitivity turn cloc...

Page 8: ...lowing statement will be provided with the equipent as required by Article 6 3 of the R TTE Directive 199 05 EC HE400T is in conformity with all essential requirements of the R TTE Directive 1999 05 E...

Reviews: