In stal la tion

HESA ad vises to make an in spection of the site to pro-
tect con si de ring the fol lowing ele ments:

Width pat tern of de tection area

The width of the beam va ries depending on the distan-
ce between the receiver and the transmitter and the
sen si ti vity le vel used. The fol lowing dia gram (Figu re 2)
allows you to de termine the ma ximum width of the
beam that is at half of the di stance of the bar rier.

Mount ing height

The mo unting height from the ground of the bar rier de -
pends on the in stal la tion re qui re ments but espe cial ly
must be de ter mi ned con si de ring that the in crea se of
the height in creases also the the length of the un cove-
red area that is the area to the ground not co vered by
the beam of the barrier. This in formation is im portant
also for de termining the overlapping of two bar riers
that are crossing or that are in stalled in pa rallel. Plea -
se note that the un covered area in creases by decrea-
sing the sensitivity (see Figu re 4).

Typically the height should be of 85 cm. 

The

height is betwe en ground and the middle of the devi-
ce.
For se curity purposes we advise to overlap the ends of
the bar riers in or der to eli mi na te the un co ve red areas.
Con si de ring an avera ge sen si ti vity and a mo un ting
height of 85 cm, you should over lap for about 5,5 m
in the cor ners and for about 11 m on the rec tilinear
pro tec tions. In case the re are con se cu ti ve bar riers, the
distance between the centers should be of about 50
cm (see Figure 3).

Model HE400 mi cro wa ve barrier

DT01142 - Page 2

DOCU MEN TAZI ONE TEC NICA

TECH NI CAL DOCU MEN TA TION

0

2

4

6

8

10

12

14

16

18

20

10

20

30

40

50

60

70

80

90 100 110 120 130 140 150 160 170 180 190 200

Lunghezza della barriera (m)

Diametro

a

m

età

tratta

(m)

Fig.2: Diameter of the sensitive zone

Distance betwe en TX and RX (m)

Summary of Contents for HE400

Page 1: ...ssed so that it causes an alarm re lay to be energized When an intruder approaches the beam the energy detected by the receiver causes if the predetermined level is reached the relay to be de energize...

Page 2: ...overlapping of two barriers that are crossing or that are installed in parallel Plea se note that the uncovered area increases by decrea sing the sensitivity see Figure 4 Typically the height should b...

Page 3: ...Model HE400 microwave barrier DT01142 Page 3 DOCUMENTAZIONE TECNICA TECHNICAL DOCUMENTATION Fig 4 Installation height of devices Fig 3 Attention to dead zones...

Page 4: ...r parking guards may be used to protect equipment from damage from vehicles see Figure 7 Best security Choose the location that will provide best security yet be free from nuisance alarms Al ways loca...

Page 5: ...tput N C for protection against unauthorized openings movements or tampe ring In normal conditions there is a NC circuit 0 ohm voltage free The opening of the contact is determined by a movement of th...

Page 6: ...t of the trasformer PT0 PT1 tamper circuit output N C for protection against unauthorized openings movements or tampe ring In normal conditions there is a NC circuit 0 ohm voltage free The opening of...

Page 7: ...X speed detection turn clockwise to lower this parameter and on the op posite for increasing it see on the printed circuit for re ference signals PT5 Trimmer for adjusting the RX sensitivity turn cloc...