Description
of the menu navigation and adjustement values
6
19
6.4
Parametermenu (P)
Name
P01
CODE:
Code-entry
P02
Power max:
Setting the maximum power of the boiler (30-100%).
P03
Minimum requirement
Setting up the minimal boiler set temperature (65-75°C) during operation.
P04
Control-hysteresis (code protected):
Setting up the control hysteresis (it is a temperature, which exceeds regulated the required boiler
temperature). (3-20)
P05
Residual heat temperature (code protected):
Temperature, which indicates, how far the boiler must be "emptied" when reloading or when the
back flow pump switched on.
P06
Fuel
Setting up predefined fuels
P07
Buffer Must temperature
Setting up Must-temperature (20-95), this is the buffer bottom temperature, which the buffer
bottom will charged.
P08
Difference temperature
Setting up the temperature difference (3-25) between heat supplier (= boiler) and buffer
temperature bottom for excitation of the buffer loading pump.
P09
Temp. increase
Setting up the temperature increase (5-15) of the required temperature.
P10
Balance tank
After the boiler switched off (e.g.: burner cleaning) is compared, if the buffer temperature in the
upper area has the required boiler temperature.
By pressing the button:
"On/Off":
The equipment is switched on/off
„F1“:
The first digit of the code is increased
„F2“:
The second digit of the code is increased
„F3“:
The third digit of the code is increased
„F4“:
The entry will be confirmed.