7
Installation method
5.
Installation method
①
Install this machine in the place where it can be easily viewed from the Transmitter and
also an electric wave can be stably received.
②
Set the antenna so that it is not parallel to the metal plates and keep away it from metal
plates as far as possible.
③
Feed the stable power supply (DC12V) with less variation.
④
Make a wiring for the output terminal block.
Output turns on with relay contact. Once output turns on, short-circuited condition is made
between terminals.
Once the rated contact load is exceeded, inner circuit might be damaged. Use an extreme
care.
Rated load voltage AC/DC30V per point
Rated load current 0.5A per point
Connection method Screw terminal(M3.5) 8-piece
Internal
Circuit
ID1-1
L
+
-
+ -
30VAC
or
30VDC
Internal
Circuit
ID2-2
ID2-2
L
+
-
+ -
30VAC
or
30VDC
ID1-1
<TWF-600R
Output terminal Block>
<External Connections>
+
-
+-
L
+
-
+-
L
Summary of Contents for POKAYOKE TWF-600R