21D-265C
47
Basic operation
6-12. Setting the Advancement judging function
Key [9]
Objective type=
**
3
,
1523
The Advancement judging function allows the outputting from
“Advancement judging +
“terminal and “Advancement judging - “terminal when the absolute value of Advancement
has exceeded the judging value of [+] side and [-] side, which was preset. You have to set
both for plus side and minus side.
Once
“With/without of advancement judging” is set to “No” in the Function settings, this
function is disabled, thus [9] key cannot be selected.
①
Press [9] key.
②
To set the + side judging, input [+].
③
Input + side judging value.
<e.g.>To set + 10, input [1] and [0] in this order.
If you have inadvertently pressed a wrong numerals, press [CLR] key and input
once again.
④
Here, press [ENT] to set the + side judging value.
*If you have inadvertently pressed a wrong numerals, press [CLR] key to get back to the
Step
①
.
*Also for the - side judging value, take setting in the same manner as above.
{9}A.J.V
+:+side
-:-side
※A.J.V:
advancement judging value
+A.J.V
[****]
Input
[
]
[
*
]present data
+A.J.V
[****]
Input
[
10]
[
*
]present data
+side judging value setting range:0-9999
- side judging value setting range:0-9999