Operating Instruction
95990001
www.herthundbuss.com 54
EN
Function selection:
Use the arrow buttons to select
DIAGNOSE
SENSOR
andpresstheenterkeyforthedi-
agnosis.
Readout of sensor in setting Wheel: 1
The AirGuard will now read out the sensor.
The sensor reaction time may vary accord-
ing to sensor type and brand.A successful
read-outisconfirmedwithabeep.
The following image is an example of the
datadisplayofasensorthathasbeenread.
Vehicletype
Tyrepressure
(psi/bar/kPa)
Sensor ID
Batterystatus
Tyre
temperature
(°C/°F)
Sensorfrequency
TIP
Renewed pressing of the Enter
keystartstheactivationprocessfor
"sleeping" sensors. Example: After
lengthyperiodsofinactivitythesensors
switchtorestmodetosavethebattery.
Please note:
The AirGuard does not interpret any
sensor values. It gives the sensor data
according to the OE protocol of the
respective vehicle. Not all sensors
transfer the displayed information.
Readout of several sensors in setting
Wheel: 4
Thedisplayshowsavehiclepictogram.The
up/down keys on the device can then be
usedtoselectthetyreyouwishtoreadout.
Thisalsoincludesthesparetyre.
A flashing display means that there is no
stored data for the tyre. A steady display
meansthatdatahavealreadybeenreadout
andstoredforthetyre.
Itisthusalwayspossibletoseewhichtyres
have been dealt with so far.
Summary of Contents for AirGuard 95990001
Page 20: ...Bedienhinweis 95990001 www herthundbuss com 20 DE 1 2 3 4 5 6 7...
Page 62: ...Operating Instruction 95990001 www herthundbuss com 62 EN 1 2 3 4 5 6 7...
Page 104: ...Notice d emploi 95990001 www herthundbuss com 104 FR 1 2 3 4 5 6 7...
Page 128: ...www herthundbuss com 128 Notizen Notice Remarques...
Page 129: ...129 Notizen Notice Remarques...
Page 130: ...www herthundbuss com 130 Notizen Notice Remarques...
Page 131: ...131 Notizen Notice Remarques...