background image

T-BT Battery powered 

wireless thermostat

Calibration

Calibration is a process to alter the temperature of the T-BT up or down in order to
align the unit with another thermostat.

The T-BT can be calibrated 5

°

C up or down from the default of 0 (no calibration). You

can calibrate in steps of 0.5

°

C.

Calibrating UP (i.e. +1

°

C etc) means the T-BT will display a higher temperature than

the present one being shown. Use this when you think the T-BT is under-reading
compared with another thermostat.

Calibrating DOWN (i.e. - 1

°

C etc) means the T-BT will display a lower temperature

than the present one being shown. Use this when you think the T-BT is over-reading
compared with another thermostat.

When adjusting the T-BT Time & Temperature settings using the SET button,
calibration is the final setting you can change. The default is 0. Use + or

keys to

adjust this figure up or down.

2 Year Warranty

Register

your

product

here

https://www.herschel-

infrared.com/customer-service/warranty-registration/ or via the QR
code.

Within two years from date of purchase Herschel will repair or replace
the T-BT where the fault is due to defects in materials or workmanship.
This warranty is for standard domestic use only and excludes commercial
uses. In the event of a warranty claim please visit the Customer Service
area of the Herschel Website and follow the Warranty Claim process.
You will need proof of purchase.

A prerequisite for validity of the warranty is use in accordance with the
conditions specified in this manual. Any further warranty or claims are
excluded.

Note your serial number here for future reference.

The warranty covers the repair or replacement of the defective product only and Herschel shall have
no liability for installation costs or consequential loses however incurred. The decision to repair or
replace will rest solely with Herschel and any replacement will be as close as possible in specification
to the failed unit. Removing the serial number will void the warranty. The warranty will also be void
if the unit has been tampered with in any way.

The product rating label must be left on the unit.

Herschel Infrared Ltd will assume no responsibility for scratches on the thermostat display or case
after first use.

Summary of Contents for T-BT

Page 1: ...gn requirements for local space heaters 2009 125 EC Original instructions covering Herschel XLS controllers produced from 08 2019 onwards Technical Information Power Supply 2 x AA Batteries not includ...

Page 2: ...l s open window technology and an adaptive start function ensuring your room is always at the right temperature with the least energy use The T BT can be paired to more than one heater meaning multipl...

Page 3: ...Gently open the T BT case using a flat headed screw driver 2 Use the rear of the casing as a template for marking your mounting holes and drill the holes 3 Insert rawlplugs not supplied 4 Gently scre...

Page 4: ...each other and try the above process again 6 Press the Power button on the T BT to start using it to control the heater Setting Time Calibration Operating Instructions 1 Press the SET button on the T...

Page 5: ...you to save energy by setting a lower temperature while you are away The HOL mode has a day counter feature allowing you to set the number of days you are away and return the heating to normal operati...

Page 6: ...the time Press PRG to advance to the temperature setting Use or buttons to change the temperature Press PRG to advance to the next period Repeat the above steps to complete the 4 periods for each day...

Page 7: ...w will be displayed Pressing the Power button on the unit will resume normal operation or waiting for 30 minutes will also restore normal operation Open Window detection will only work if the feature...

Page 8: ...o years from date of purchase Herschel will repair or replace the T BT where the fault is due to defects in materials or workmanship This warranty is for standard domestic use only and excludes commer...

Reviews: