Page 1: ...Owner s Manual Version 01 2021 Petrol LPG CNG Generator 8896231 8896322 8896324 ...

Page 2: ...fidence you have shown in the HERON brand by purchasing this generator This product has been tested for reliability safety and quality according to the prescribed relevant norms and regulations of the European Union with additional testing for compliance with NZ Aus standards Contact our customer and consulting centre for any questions at www madalbal co nz Manufacturer Madal Bal a s Průmyslová zó...

Page 3: ...ectrical items Example a welding unit which cannot be connected to a 15 A 230 V power socket which on these generators is protected by a 15A circuit breaker Thanks to the 32 A 230 V socket the generator can also be used for powering electrical distribution grids TN C S or TN C grids as a backup power source 15A 32A 5 5 8896231 8896322 8896324 The generators have an electrical start only model 8896...

Page 4: ... 9 DC circuit Breaker 10 ATS Connector not equiped 11 Hz H V Display 12 AC Outlet X2 13 AC Breaker 14 Engine switch 15 Small front cover not equiped 16 Big front cover not equiped 17 Bolt for front cover not equiped 18 Fan not equiped 19 LPG CNG switch 20 Air filter 21 Axle with brake not equiped 22 Choke lever 23 Battery 24 Oil Alarm 25 Pilot lamp 26 Recoil starter 27 ATS controller not equiped 2...

Page 5: ... controller 23 ATS model switch 24 ATS stop start switch 25 City power indicator 26 Generator indicator 27 Output indicator 28 Loads terminal 29 Generator terminal 30 City power terminal 31 ATS Connector 32 Grounding terminal 33 Fuse 9 9 8896231 8896322 8896324 Assembly Model 8896231 Tools Required 1 Adjustable wrench 2 Philips screwdriver Instructions Very little assembly is required for this mod...

Page 6: ...nuts secure one axle assembly to the generator frame Note there are 4 pre drilled holes in the frame for each axle located in the frame member under the engine 3 Repeat step 2 for the second axle assembly 4 Using 1 off bolt and nut secure one of the rubber feet to the metal foot bracket 5 Repeat step 4 above for the second rubber foot 6 Using 2 off bolts and nuts secure the foot assembly to the ge...

Page 7: ... position 2 Set the circuit breaker to the OFF position 3 Set the Engine switch to the ON position Manual Start 4 Pull the rip cord to start the engine Electric Start 4 Push the engine switch to the START position once the engine is running release the switch 5 Once the engine is running smoothly move the choke to the OPEN position 6 Connect electrical devices to the generator ensuring that their ...

Page 8: ...so that the oil can be completely drained 3 Check the drain plug gasket oil filler cap and 0 ring If damaged replace 1 Oil drain plug 2 Gasket 3 Oil filler cap 4 Reinstall the oil drain plug Drain Plug Torque 30 Nm 3 0 kgf m 22 lbf ft 5 Add engine oil to the specified level Recommended oil SAE 30 or lOW 30 Oil Quantity 8896231 600ml 8896322 1100ml 8896324 1300ml Air Filter Maintenance 1 Remove the...

Page 9: ...ls to Start Battery not connected or incorrectly connected electric start models only Connect Battery per manual No Fuel Open fuel stopcock No spark Clean and reset gap or replace spark plug Low oil level Fill oil to correct level Low fuel Fill the fuel tank Battery not charged electric start models only Charge battery Generator starts on LPG CNG but runs rough or RMP unsteady Pressure of gas supp...

Page 10: ...eipt of pur chase 03 Warranty Period duration includes stated months or hours whatever comes sooner Warranty Period for Domestic Use Only Hybrid Generators Models 8896231 8896322 8896324 24 months 2000hrs Commercial Warranty Period is 50 of the Domestic Warranty period or 1000hrs whatever comes first Coverage Detail 04 We will replace or repair at our option without charge for parts or labour at a...