Hermle Z 130 M Operating Manual Download Page 19

 

III 

Z 130 M_V1.15 

© Hermle Labortechnik GmbH 

 

Redemption form / Decontamination certificate 

 

Decontamination certificate at goods return delivery 

 

Enclose at all returns of equipment and assemblies absolutely! 

The  completely  full  declaration  about  the  decontamination  is  prerequisite  for  the  assumption  and  further 
processing of the return. If no corresponding explanation is enclosed, we carry out decontamination with costs at 
your expense. 

Surname; last name: 

 

_____________________________________ 

Organization / company:   

_____________________________________ 

Street: 

 

 

 

_____________________________________ 

ZIP CODE:  

 

 

_____________ place:____________________ 

Telephone: 

 

 

_____________ fax:____________________ 

E-Mail: 

 

 

 

_____________________________________ 

 

Pos.

Crowd

Decontaminated 

object

Serial number

Description / Comment

1

2

3

4

 

        Are these parts listed above in touch with the following substances? 

 

Health endangering watery solutions, buffers, acids, alkalis:

……….............. ..... 

 Yes 

 No 

Potentially infectious agents

: ………………………………………………………... 

 Yes 

 No 

Organic reagents and solvent

: ………………………………...……..................... 

 Yes 

 No 

Radioactive substances

: ………………………………………..…

 

α

..

 

β

..

 

γ

.. 

 Yes 

 No 

Health endangering proteins: 

…………………………………….……………......... 

 Yes 

 No 

DNA: ………………………………………………………………………………….…. 

 Yes 

 No 

These substances have reached the equipment/assembly

? ………………………….. 

 Yes 

 No 

Which one, if yes:   

 

 

 

 

 

 

 

 

 

 

 

 

________________________________________________________________ 

Description of the measures for the decontamination of the listed parts: 

 
 
 

 

 

I confirm the proper decontamination: 

Company/dept ._____________ place and date: ____________________________________ 

Signature of the authorized person: ________________________________________ 

 

Ple

as

e f

ill 

out i

n bl

oc

capi

ta

ls

Summary of Contents for Z 130 M

Page 1: ... Hermle Labortechnik GmbH Z 130 M _V1 15 Operating Manual for Mini Centrifuge Z 130 M ...

Page 2: ......

Page 3: ... Starting up 5 2 2 Loading rotor 5 Examples of properly balanced rotors 5 Examples for improperly balanced rotors 6 2 3 Power switch 6 3 MAINTENANCE 7 3 1 Maintenance and cleaning 7 3 1 1 General 7 3 1 2 Cleaning and disinfection of the unit 7 3 1 3 Cleaning and disinfection of the rotor 8 3 1 4 Disinfection of PP rotors 8 3 1 5 Glass breakage 9 3 2 Life time of rotors round and rectangular bucket...

Page 4: ......

Page 5: ... different density Hermle centrifuges are intended exclusively for indoor use and for use by qualified personnel Only Hermle original rotors and accessories might be used Any other use or intended use is considered improper From the resulting damage the company Hermle Labortechnik is not liable 1 2 Brief description The unit type Z 130 M is a mini centrifuge which we offer in two voltage variation...

Page 6: ...e designation of the product REF Order number SN Serial number of the product Date of manufacture Manufacturer MAX Drehzahl max allowed speed of the unit KIN EN max kinetic energy with corresponding rotor U I f Allowable voltage max current frequency P Electrical input power before operating read the operating manual Labeling standards and guidelines that are considered ...

Page 7: ... it is not installed correctly Do not operate the centrifuge when dismounted e g without housing Do not run the centrifuge when mechanical or electrical assembly groups have been tampered with unauthorized persons Do not use accessories such as rotors and buckets which are not exclusively approved by HERMLE Labortechnik GmbH except commercially available centrifuge tubes made of glass or plastic D...

Page 8: ...nit according to the standards EN 61010 2 020 Do not place the centrifuge next to a window or a heater where it could be disposed to excessive heat as the performance of the unit is based on an ambient temperature of 23 C 1 5 3 Installation Follow these steps Check whether power supply corresponds with the one named on the manufacturer s rating label which is mounted on the rear panel The line vol...

Page 9: ...ION Never attempt to remove samples until the rotor has come to a complete stop ATTENTION Do not operate the centrifuge with rotors or buckets which show any signs of corrosion or mechanical damage Do not operate with extremely corrosive substances which could damage the rotor and unit 2 2 Loading rotor Rotors must be load symetrically and with equal weight see figure 1 The adapter may only be loa...

Page 10: ...130 M_V1 15 6 Examples for improperly balanced rotors 2 3 Power switch The power swich is on the left side at the back wall of the housing see figure 3 Figure 3 Power swich Represents a loaded position Represents an empty position Figure 2 ...

Page 11: ...to the housing interior Do spray disinfectant on the device Thorough cleaning not only has its purpose in hygiene but also in avoiding corrosion based on pollution In order to avoid damaging anodized parts such as rotors reduction plates etc only pH neutral Detergents with a pH value of 6 8 may be used for cleaning Alkaline cleaning agents pH value 8 must not be used After cleaning please ensure a...

Page 12: ...ng of the rotors and accessories set them on a towel Place the angle rotors with bores down to dry them to 5 Dry the rotor cone with a soft dry and lint free cloth and look for damage Do not grease the rotor cone 3 1 4 Disinfection of PP rotors The recommended time for autoclaving 15 20 min at 121 C 1 bar ATTENTION The sterilization time of 20 min must not be exceeded Sterilization again and again...

Page 13: ...ids and caps after five autoclaving cycles Never store aerosol tight rotors or buckets closed 3 1 5 Glass breakage With high g values the rate of glass tube breakage increases Glass splinters have to be removed immediately from rotor buckets adapters and the rotor chamber itself Fine glass splinters will scratch and therefore damage the protective surface coating of a rotor If glass splinters rema...

Page 14: ...aned before the shipment for the protection of persons environment and material Please fill out the below completely form Decontamination certificate at goods return delivery see APPENDIX p III and put the decontamination form to the outside of the box We reserve the right to accept contaminated centrifuges Further on all costs occurred for the cleaning and disinfection of the units will go to the...

Page 15: ...vices in the European Community The disposal of the electrical devices is regulated within the European Community by national regulations based on EU Directive 2002 96 EC pertaining to waste electrical and electronic equipment WEEE In accordance with this any devices delivered after 13 08 2005 on a business to business basis which includes the product may no longer be disposed of in household wast...

Page 16: ... Hermle Labortechnik GmbH Z 130 M_V1 15 12 APPENDIX Table 1 Technical Data I EC conformity declaration II Redemption form Decontamination certificate III ...

Page 17: ...n Ambient conditions EN IEC 61010 1 Environment for indoor use only High Use up to an altitude of 2000 m above MSL Ambient temperature 2 C up to 35 C Max relative humidity Max relative humidity 80 for temperatures up to 31 C Decreasing linearly to 50 relative humidity up to 35 C Overvoltage category IEC 60364 4 443 II Degree of contamination 2 Class of protection I Class of protection DIN EN 60529...

Page 18: ... Product named below fulfills the relevant fundamental requirements of the EC directives and standards listed In the case of unauthorized modifications to the product or an unintended use this declaration becomes invalid Produkttyp Product type Laborzentrifugen mit Zubehör Laboratory centrifuge with accessories Typenbezeichnung Typ designation Z 130 M Einschlägige EG Richtlinien Normen Relevant EC...

Page 19: ...x ____________________ E Mail _____________________________________ Pos Crowd Decontaminated object Serial number Description Comment 1 2 3 4 Are these parts listed above in touch with the following substances Health endangering watery solutions buffers acids alkalis Yes No Potentially infectious agents Yes No Organic reagents and solvent Yes No Radioactive substances α β γ Yes No Health endangeri...

Page 20: ......

Page 21: ...Z 130 M_V1 15 Hermle Labortechnik GmbH 6 Notes ...

Page 22: ... Hermle Labortechnik GmbH Z 130 M_V1 15 ...

Page 23: ...Z 130 M_V1 15 Hermle Labortechnik GmbH ...

Page 24: ...HERMLE Labortechnik GmbH Siemensstrasse 25 78564 Wehingen Tel 0 74 26 96 22 17 Fax 0 74 26 96 22 49 Email vertrieb hermle labortechnik de Internet http www hermle labortechnik de Technische Änderungen vorbehalten HERMLE Labortechnik GmbH 2012 ...

Reviews: