HermanMiller for Healthcare
Assembly Instructions
3
1BJM4F rev D
Step 5
5.1 Drill 3 holes through mating side panels, 2 at front of cabinet (1 toward
top and 1 toward bottom) and 1 at back in middle of cabinet. Holes should be
inset 3 “ from front edge of side panel and 3” from back inside surface of back
panel. Locate holes up or down as needed.
5.2 Attach cabinets together with 3 Clamping Screws in ganging hardware
pack CH110.
3”
3”
Drill Hole
Drill Hole
Drill Hole
Clamping
Screw
Hinge Adjustment:
The bottom surface of the door should be flush with the bottom of the cabinet
frame. To adjust door up, turn cam screw clockwise on right hinge. To adjust
door down, turn cam screw clockwise on left hinge. Adjust both hinges on
each door as necessary until proper door height is set.
To adjust door up/down:
Cam Screw
Step 6
6.1 On each cabinet, drill 3/16” hole 5” down from top through back of
cabinet. Note: Do not drill through wall cleat behind cabinet.
6.2 Install #10 screw to attach case to wall cleat. This is for anti-
dislodgement of unit.
Wall Cleat
Case
Drill Hole
#10 Screw
5”
To adjust door(s) left or right and or to tilt door(s) left or right, use lateral
adjustment screw in hinge arm. Adjust screws in both upper and lower
hinges to move SCREW doors left or right, or adjust screw in one hinge to
tilt door left or right. Turning screw(s) clockwise moves door towards hinged
side. Counter-clockwise to move door away from hinged side. Turn counter-
clockwise for opposite door movement.
To adjust door left/right:
Lateral Adjustment Screw