11 

Advantages: 

x

 

The stove will not use the room air, and due 
to this you will not lose hot room air, and high 
air renovation ratios will not be necessary. 

x

 

In case of low pressure inside the room, the 
exhaust will never get into the room. 

x

 

CO generation inside the room and its 
dangerous consequences will be avoided. 

Always bear in mind that the air inlet to the 
appliance is made by means of the connector. It 
should never be possible to cap this inlet. Either 
on the stove or on the outside. Nor should it be 
possible for the connection tube to be crushed or 
obstructed by something. A grating is required on 
the intake. 

The position of the air intake should be protected 
from the wind to avoid a possible positive or 
negative pressurisation of the combustion. 

Please note that this accessory is a connector that 
serves to facilitate the installation and has no 
control system by itself. There are control systems 
on the market that can be installed together with 
this accessory to control the air intake and to 
complete a proper installation. 

When you install an air intake from outside you 
should always have the primary air valve closed 
(Fig. 2). 

The diameter of the connector pipe is prepared 
for installing pipes of 80 mm in diameter, which is 
a standard measure. The installation of the 
connector is easy and you can see it in this manual 
in section 10. 
 

 

5. CLEANING 

FRONT AND PAINTED CAST IRON DOOR. 

Always use dry cloths. 

GLASS ON THE DOOR. 

Never attempt to clean the glass while the stove is 
in operation. We recommend that you use 
Hergóm glass cleaner when it is cold. 

Replacement.

 The glass on your stove is 

manufactured especially for wood-burning stoves. 
If it breaks it should be replaced with glass that 
has the same characteristics. Please contact the 
authorised Technical Support Service to provide 
the proper glass, accompanied by the assembly 
instructions and gaskets. 

GASKETS AND SEAL 

At the start and halfway through a season it is 
recommended to carry out a visual check on the 
condition of the gaskets (doors, glass, etc.) and 
seal of the parts, in case it is necessary to replace 
or repair them. 

ASH. 

The cast iron stove is equipped with a ash pan 
located under the base of the stove.  
To remove the ashes, remove the andiron and cast 
iron grill (rectangular cover) which hides it using a 
protective glove, and remove it from the stove so 
as not to hinder the cleaning (Fig. 7 and 8). 

Move the ash to the ash pan with a scraper or a 
brush. Remove the ash pan from its housing and 
clean it of ash (Fig. 9).  

For safety reasons the ash pan cannot be 
removed with the door of the stove closed. 
 

The responsibility for manufacturing defects will 
be submitted to the criterion and verification of 
the company's technicians, but is limited to the 
repair or replacement of its products, in 
accordance with the warranty that comes with 
each product. 

 

 

Summary of Contents for HGB-70

Page 1: ...HGB 70 INSTRUCCIONES PARA INSTALACI N USO Y MANTENIMIENTO INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE ISTRUZIONI PER L INSTALLAZIONE USO E MANUTENZIONE...

Page 2: ...liance is protected with a special heat resistant paint for high temperatures During the first few times that you start it up it is normal for it to smoke slightly as some of its components evaporate...

Page 3: ...nect an air intake from the outside 3 OPERATING INSTRUCTIONS Once installed in its final destination check the seal of all of the joints to prevent the entry of air from outside that is detrimental to...

Page 4: ...void any smoke escaping being opened only for reloading It is recommended that when you open the door of the stove to load fuel you should do it slowly Direct draught control valve This valve is used...

Page 5: ...can see it in this manual in section 10 5 CLEANING FRONT AND PAINTED CAST IRON DOOR Always use dry cloths GLASS ON THE DOOR Never attempt to clean the glass while the stove is in operation We recommen...

Page 6: ...operating your stove with solid fuels whatever the make These risks can be minimized if you follow the instructions and recommendations that we have provided in this manual x When you put the stove in...

Page 7: ...g its products Heat resistant paint for cast iron and sheet metal parts Refractory paste to improve airtightness and seals Anti soot powerful catalyst that facilitates the elimination of unburnt resid...

Page 8: ...20 9 MONTAJE PIEZAS INTERIORES INDOOR COMPONENTS ASSEMBLY MONTAGGIO COMPONENTI INTERNI 6 8 9 1 2 3 4 A B C D E A B 5 7...

Page 9: ...21 10 11 12 15 16 C D 14 13...

Page 10: ...ara el desmontaje de los deflectores B D proceder de forma inversa Proceed in the reverse order for removing the baffles B D Per il smontaggio dei deflettori B D procedete in modo inverso 18 19 17 20...

Page 11: ...23 10 MONTAJE CONECTOR ENTRADA AIRE EXTERIOR ASSEMBLY OF AIR INTAKE CONNECTOR FROM OUTSIDE MONTAGGIO PRESA D ARIA ESTERNA 1 2 3 7 5 6 4...

Page 12: ...24 11 DIMENSIONES GENERALES GENERAL DIMENSIONS DIMENSIONI...

Page 13: ...luidos los hogares abiertos que utilizan combustibles s lidos Requisitos y m todos de ensayo modificada por UNE EN 13229 AC UNE EN 13229 A1 2003 y UNE EN 13229 2002 A2 2005 ADVERTENCIA Su Hogar de Emp...

Page 14: ...26 13 DESPIECE Y REPUESTOS DISASSEMBLY AND SPARE PARTS ESPLOSO E RICAMBI...

Page 15: ...27...

Page 16: ...28...

Page 17: ...MBI A1 A3 A8 9920454 A1 9920393 A3 9920394 A8 9920392 B1 9920395 C1 9920405 C3 9920452 C8 9920404 C10 9920403 C11 9920406 C12 9920407 C13 9920396 C21 9920453 C22 9920401 C23 9920399 C26 9920400 C27 99...

Page 18: ...30 PLACA DE CARACTERISTICAS SPECIFICATIONS PLATE TARGHETTA DELLE CARATTERISTICHE...

Page 19: ...31...

Page 20: ...32 C digo C03521 Versi n 1 INDUSTRIAS HERG M S A SOTO DE LA MARINA Cantabria Apartado de Correos 208 39080 Santander ESPA A Tel 0034 942 587 000 E mail hergom hergom com www hergom com...

Reviews: