Installation Manual                                                                                                

                                                                                                         

 

Module Installation 

 
For trouble-free operation, follow these simple installation guidelines: 
 

  Electrical wiring used to connect the MicroZone modules 

must meet all state and local 

regulatory requirements

. Wire rated for 600 volts (minimum) is recommended. 

  Standard electrical conduit or raceways can be used to route wiring for the MicroZone 

modules.   

  Do not install the modules in the same room where the animals live. A separate room or 

hallway is a preferred location.   

  Do not install the modules where they will be subjected to harsh chemicals. 

  When fastening the covers to the units, be sure to only compress gaskets to ½ their original 

size. This will result in a better seal to repel any moisture or dirt that may get into the units 
and prevent normal operation.  

Wiring/Setup  

 
Below is a simplified diagram to show how the MicroZone units interconnect for a 120V 
installation.  A wiring diagram for 240V installation is on the next page.  A qualified electrician can 
easily wire the system with standard (600V-rated) wire. 
 

 

 

Summary of Contents for MicroZone MC110A

Page 1: ...Installation Manual 10 31 2014 0 10V Automatic Lamp Mat Heating Control Installation Operation...

Page 2: ...on Overview 3 Mounting and Wiring 3 Conduit and Connections 3 Module Installation 4 Wiring Setup 4 Wiring Multiple MPM100 Power Modulators into a System 4 Wiring MPM100 Power Modulator 6 Wiring Instru...

Page 3: ...Place the controller away from motors and relays contactors that switch high current Do not install it in the same room where the animals live since the air tends to be corrosive to electronic circuit...

Page 4: ...e the animals live A separate room or hallway is a preferred location Do not install the modules where they will be subjected to harsh chemicals When fastening the covers to the units be sure to only...

Page 5: ...one system a dedicated Phase 2 wire must be run to the Modulators MPM100 s This will prevent load current on the Phase 2 wire from interfering with proper operation of the MPM100 modulator For 120V op...

Page 6: ...ch power modulator will have its own heating device circuit wiring Wiring MPM100 Power Modulator Ensure power is removed from the power distribution panel before wiring in the heating device feed circ...

Page 7: ...ring Multiple MPM100 Power Modulators into a system section above for more information MPM100 Power Modulator Connect the MPM100 s BLACK wire to the power panel Phase 1 Connect the MPM100 s WHITE wire...

Page 8: ...actory for repair Flashing AUTO indicator Communications between the Controller MC110A and the Modulator have failed The communications wiring may have been damaged or become disconnected Intermittent...

Page 9: ...f 12 MPM MicroZone Power Modulators within 500 feet using 18AWG two conductor wire MPM100 MicroZone Power Modulator Input Power 120 240VAC 16A Maximum Load Rating 0 120VAC or 0 240VAC 2kW 120V or 4kw...

Reviews: