background image

Operation Manual                                                                                                                                                                                                                                         
 

BinTrac Breeder Control Operation Manual

 

Ver. 1.01 Rev 1.04

 

Part # MAN-000008

 

Batch 

Enables you to set the batch option from 

LoAd

 to 

u.LoAd

.  

LoAd

 is used when you want material batched into a bin. 

Based on the gross weight of the bin, material is batched into the bin until the batched amount equals the gross 
amount. 

u.LoAd

 is used when you want material batched out of a bin. In this case, the bin is holding a bulk amount of 

feed and will batch out the programmed batch amount. 

 

1.  Press the SELECT key to enter menu. 

2.  Use the 

 or  

 keys to select Load or uLoad. 

 

Segmented display: 

 

 
 
 

Rated 

The average rated output, in millivolt/volt of the load cells.  DO NOT CHANGE unless necessary.  Every standard load 
cell has a rated output, specified in mV/V.  If using load cells other than the Herdstar load cells, adjust this value 
appropriately.   

 

1.  Press the SELECT key to select the desired Bin. 

2.  Use the 

 key to increase the rated output by 0.001.

 

3. 

Use the 

 key to decrease the rated output by 0.001.

 

 

 

Segmented display: 

 

 

 

Capacity 

 

Sets the system capacity of each bin.  The system capacity is the sum of all the load cells rated capacity. 

When 

setting for kilograms, convert the total system capacity to kilograms.   
Ex:   Six leg bin with six 10k loadcells, capacity setting for pounds is 60,000. Capacity setting for kilograms is 
27,215. 

 

1.  Press the SELECT key to select the desired Bin. 

2.  Use the 

 key to increase the value by 1 unit. 

3.  Use the 

 key to decrease the value by 1 unit. 

 
 
 

 

Segmented Display: 

 
 

 

 

 

 

 

 

 

rAtEd 

 cAP 

BAtch 
Atch 

Summary of Contents for Bintrac

Page 1: ...Operation Manual 12 1 2012 Breeder Control Operation Manual Patented U S Patent No 7 980 129 and Patents Pending...

Page 2: ...n Option in Setup mode 5 Options in Setup Mode 6 Setup Version 1 0 and higher 6 Serial Data Command Set 6 Batch 7 Rated 7 Capacity 7 Increment Value 8 Full Value 8 Zero Value 8 Year 9 Month 9 Date 9 H...

Page 3: ...es the signals from all brackets to minimize errors that could result from voids holes in the material Smart Summing Box A single Smart Summing Box per bin communicates the current reading on the leg...

Page 4: ...key for approximately 8 10 seconds The bin level gauge will go blank and all of the bin selector indicators will illuminate showing their current status 1 Press the SELECT key to select the desired bi...

Page 5: ...ce is powered up it will automatically enter SETUP mode and display the Ver 2 This method requires you to hold the SELECT button down for approximately 10 seconds at which time SETUP mode will be disp...

Page 6: ...roadcast ASCII weight data will be serially broadcast approximately once ever second RUN Enable communications to peripheral devices Must be enabled when BinTrac Monitor is connected to BinTrac Remote...

Page 7: ...ad cells DO NOT CHANGE unless necessary Every standard load cell has a rated output specified in mV V If using load cells other than the Herdstar load cells adjust this value appropriately 1 Press the...

Page 8: ...units Segmented display Figure 2 Full Value Sets the maximum weight of a full bin either in pounds or kilograms It is how much material the bin can hold This is for calibration of the LED bar graph le...

Page 9: ...the current Minute Segmented display Station ID Value Sets the Station ID of the device For devices interfacing with a Site Console the Station ID must be set within 100 131 When interfacing the devic...

Page 10: ...CT key to see the software version number Segmented display Smart Summing Box Software Version Version 3 0 and higher Displays each of the connected Smart Summing Boxes programmed software version num...

Page 11: ...h run control status run or Stop 6 Use the or keys to enable or disable batch run control 7 Press SELECT to start Batching if run was selected The batch run will begin immediately Scheduled Batch Run...

Page 12: ...while a batch is running and the weight increases by 50 lbs or more in the bin the BinTrac WBBS will pause the batch and switch to FILL batching mode until FILL is completed 4 The unit will remain in...

Page 13: ...oadcell no bin This means that the Smart Summing Box for the selected bin is not communicating Check for broken wires or loose connections or Smart Summing Box is not correctly configured or faulty lo...

Page 14: ...ranty sets forth Buyer s sole and exclusive remedies for any defect in the goods The rights and obligation under this warranty may not be assigned or delegated to a third party by Buyer without the pr...

Reviews: