Operation Manual
BinTrac Breeder Control Operation Manual
Ver. 1.01 Rev 1.04
7
Part # MAN-000008
Batch
Enables you to set the batch option from
LoAd
to
u.LoAd
.
LoAd
is used when you want material batched into a bin.
Based on the gross weight of the bin, material is batched into the bin until the batched amount equals the gross
amount.
u.LoAd
is used when you want material batched out of a bin. In this case, the bin is holding a bulk amount of
feed and will batch out the programmed batch amount.
1. Press the SELECT key to enter menu.
2. Use the
or
keys to select Load or uLoad.
Segmented display:
Rated
The average rated output, in millivolt/volt of the load cells. DO NOT CHANGE unless necessary. Every standard load
cell has a rated output, specified in mV/V. If using load cells other than the Herdstar load cells, adjust this value
appropriately.
1. Press the SELECT key to select the desired Bin.
2. Use the
key to increase the rated output by 0.001.
3.
Use the
key to decrease the rated output by 0.001.
Segmented display:
Capacity
Sets the system capacity of each bin. The system capacity is the sum of all the load cells rated capacity.
When
setting for kilograms, convert the total system capacity to kilograms.
Ex: Six leg bin with six 10k loadcells, capacity setting for pounds is 60,000. Capacity setting for kilograms is
27,215.
1. Press the SELECT key to select the desired Bin.
2. Use the
key to increase the value by 1 unit.
3. Use the
key to decrease the value by 1 unit.
Segmented Display:
rAtEd
cAP
BAtch
Atch