background image

Installation and Operation Manual 

HL-10C Installation Manual Rev 2.0

 

4

 

Part Number MAN-000015

 

 

5.  The unit has an 8-position dip switch that needs to be set up for configuration. Switches 1, 7, and 8 are set to ON 

from the factory.  See 

Table 2

 for dip switch identification. 

 

DIP 1 

Lower bit of 0x40 offset CANopen device address. This DIP is set if the CANopen 
address should be 0x40 + 0x01 

DIP 2 

Upper bit of 0x40 offset CANopen device address. This DIP is set if the CANopen 
address should be 0x40 + 0x02 

DIP 3 

Unused 

DIP 4 

Unused 

DIP 5 

Unused 

DIP 6 

LB/KG Units setting. This DIP is set if the BinTrac is configured using kg units. 

DIP 7 

Use CANopen setting. This DIP is set if the Can bus controller should use the 
CANopen protocol. Otherwise it uses the old (CAN Classic) communications routine. 

DIP 8 

120 Ohm Resistor. This DIP is set if the 120 Ohm termination resistor should be 
applied to the CAN bus line. 

 

 

BinTrac Indicator Setup 

The BinTrac Indicator must be set up for peripheral devices. Access the SETUP menu on the BinTrac Indicator by 
pressing and holding the BIN key for until SETUP is displayed on the screen, then release BIN key. With SETUP 
displayed, press the BIN key until BIN D is selected. Use the UP/DOWN arrows to enable peripheral devices (BIN D LED 
is solid ON). 

The Bin LEDs indicate configuration options as being enabled (solid on) or disabled (flashing). 

Bin A 

– Configures BinTrac Monitor as a Remote Display. 

Bin B 

– Enable ASCII Serial Communications Command Set 

Bin C 

– Enable Weight Broadcast. 

Bin D 

– Enable communications to peripheral devices. 

This must be enabled when BinTrac Indicator is connected to the HouseLink HL-10C. 

LED Operation 

CAN Bus Status LED: 

SLOW FLASH 

– This indicates the unit is communicating and operating normally.  

STEADY ON 

– This indicates the unit is not communicating but has power.  

NO LIGHT 

– The unit doesn’t have an adequate power source 

BinTrac Status LED: 

SLOW FLASH 

– This indicates the unit is communicating and operating normally.  

FAST FLASH 

– This indicates the unit is in TEST mode. 

STEADY ON 

– This indicates the unit is not communicating but has power.  

NO LIGHT 

– The unit doesn’t have an adequate power source 

 

Table 2 

Summary of Contents for BinTrac HouseLink HL-10C

Page 1: ...Installation and Operation Manual HL 10C Installation Manual Rev 2 0 Part Number MAN 000015 Installation and Operation Manual HouseLink HL 10C...

Page 2: ...rdstar com Table of Contents Description 3 Installation 3 BinTrac Indicator Setup 4 LED Operation 4 CAN Bus Status LED 4 BinTrac Status LED 4 Testing and Calibration 5 Reset Test button 5 CAN Open Set...

Page 3: ...separately connect the GREEN wire from the Smart Summing Box to the COM terminal in the HouseLink HL 10C and the White wire from the Smart Summing Box to the COM terminal in the HouseLink HL 10C 3 Con...

Page 4: ...ral devices Access the SETUP menu on the BinTrac Indicator by pressing and holding the BIN key for until SETUP is displayed on the screen then release BIN key With SETUP displayed press the BIN key un...

Page 5: ...the unit will output 25 full scale weight Test 3 Press the Reset Test button on the board three times and the unit will output 50 full scale weight Test 4 Press the Reset Test button on the board four...

Page 6: ...ess CAN ID and if it is connected Utilize address 41 for bins 1 4 and address 42 for bins 5 8 Technical Installation Manual installation Silo weighing boxes Select the number of BinTrac bins enabled T...

Page 7: ...lassic Setup The following two settings must be configured when using properly on the CAN bus controller to allow for accurate weight communication with the BinTrac system 1 Set Calibration value to s...

Page 8: ...Specifications CAN Bus version Compatible with ISO 11898 STANDARDS Operating Temperature Range 40 C to 60 C 40 F to 140 F Operating Voltage Range 10 5 VDC to 27 0 VDC Humidity 5 to 95 non condensing E...

Page 9: ...Installation and Operation Manual HL 10C Installation Manual Rev 2 0 Part Number MAN 000015 Wiring Diagram...