Status
Description
NOTICE! Reset must be performed only after
lamp exchange.
No action required.
Collective fault (UV lamp)
LED colour: red
Lighting mode: permanent
Malfunction at the device, system inactive.
The following root causes may exist: UV lamp or
electronic power supply (EPS).
Root cause/action:
Both UV lamps are defective and/or the electronic
power supply (EPS) is defective.
è
Replace UV lamp or electronic power supply.
Collective fault (power sup-
ply)
LED colour: red
Lighting mode: permanent
Malfunction at the device, system inactive.
The following root causes may exist: Electronic
power supply (EPS).
Root cause/action:
Housing lid not correctly closed.
è
Close housing lid properly (must engage aud-
ibly).
Thermal fuse has tripped.
è
Allow the system to cool down.
Power supply is defective.
è
Replace power supply.
More than one fan have failed.
è
Replace all fans (fan replacement kit).
Collective fault (fan)
LED colour: red
Lighting mode: permanent
Fan malfunction
Root cause/action:
At least two fans have failed or one fan has failed
and the set fan speed of the active fans is insuffi-
cient.
è
Replace all fans (fan replacement kit).