9)
Initialize
Open the front panel, press the setup button for 6 seconds, and emits one sound ¡Di---¡ (short) and ¡Di---¡ (long), the green and Red lights
will flash, the Initialization is successful. And if it emits three sound ¡Di---¡ (short), the Initialization is failed. Initialization will delete all the
master fingerprints and common fingerprints.
Note: each time when it reads the fingerprint successfully, it will emit one sound ¡Di---¡. Then you have to move the finger and then you can
continue.
: Notes
Ⅴ
1.
When powering on, it emits a sound ¡Di---¡, the Red light and Green light flash: Powering up successfully.
2.
When powering on, it emits ¡Di---¡ (long), ¡Di---¡ (short), ¡Di---¡ (long), ¡Di---¡ (short), that means failed to connect with Fingerprint Sensor
part, test the wiring.
3.
When initializing, it emits ¡Di---¡ (short), ¡Di---¡ (long), and the Green and Red lights flash alternately: Initialization success.
4.
When reading the fingerprint, the Red light flashes continually, and signal light do not turns on: Reminds to move the finger.
5.
If it emits ¡Di---¡ (long), ¡Di---¡ (short), ¡Di---¡ (long), ¡Di---¡ (short) when enrolling fingerprints, that means fingerprints are full.
6.
If it emits ¡Di---¡ (long), ¡Di---¡ (short), ¡Di---¡ (long), ¡Di---¡ (short), that means the User Fingerprints have been deleted.
7.
If it emits three sounds ¡Di--- Di--- Di---¡ when enrolling fingerprints, that means the fingerprint has been enrolled.
8.
If it emits three sounds ¡Di--- Di--- Di---¡ when deleting fingerprints, that means the fingerprint is not existing.
9.
If the Green lights keep on while adding fingerprint: Fingerprint data is being collecting, press the same finger.
10.
If the Red lights keep on while deleting fingerprint: Fingerprint data is being collecting, press the same finger.
:
Ⅵ
Technical Parameters
Item
Content
FAR
<0.0001
%
FRR
<0.01
%
Master Fingerprint
2
User Fingerprint
125
Fingerprint Angle
¡ 180¡
Working Voltage
DC 3.7V
-
4.5V
Low voltage alarm
DC 3.5V
-
3.6V
Voltage lower than 3.3V
Lock can not work properly
Static Current
7uA
Dynamic Current
200mA
Working voltage of Electronic Key
Four AA batteries, DC 6V
Battery life
Work for 10000 times
After low voltage alarm
Work for 500 times
Version
:V
1.01
,
Date
:
2011
/
11
/
15