User manual // Tria AS Power Pack
30
HENSEL-VISIT International GmbH
4 Technical Data*
Model series
Model type
Tria AS Power Pack
3000 AS
Rated energy:
3000 J
Aperture 100 ASA, t 1/60,
2 m distance, Intensity Refl.:
90 5/10
Flash
1 EH Pro 3000:
duration
t 0.5 in
3 MH 3000 Speed:
sec.
1/500
1/1700
Recycle
to 100%:
in sec.
(normal charge)
to min. output:
2,0
0,5
Power adjustment:
6,5 f adjustable in 1/10 f
Power distribution:
asymmetrical
No. of flash sockets:
4
Modeling lamp max. 230 V:
115 V:
650 W
300 W
Fuse modeling lamp:
2 x 10 AF
Mains voltage:
Multivoltage version: 230 V~ / 115 V~
Weight (kg):
12,1
Measurements
L:
with handle
B:
H:
34,5 cm
19,5 cm
41,5 cm
Code No.
Multivoltage:
3631
*: Technical changes reserved. Values attained at 230 V/50 Hz voltage.