HENSEL-VISIT GmbH & Co. KG 

Technical data* 

Model series 

Model type 

Tria Power Pack 

24 F / 24 SF

 

Rated energy: 

2400 J 

Aperture at 1 m distance, 100 
ISO, EH PRO 3000 Head, 12" 
Reflector, 1/60 sec: 

180 

Flash duration 
1x EH PRO 3000 
2x EH PRO 3000 
t 0.5 in sec, full power: 

1/600 

1/1000 

Recycling time 

Max: 

in sec 

Min: 

2.2 

0.45 

Power adjustment: 

6 f adjustable in 1/10 f 

Power output: 

75 J 

– 2400 J 

Power distribution: 

symmetrical 

No. of flash sockets: 

Modeling lamp 

Max: 

Fuse: 

2 x 650 W / 230 V 

10 AF 

Mains voltage: 

230 V~ / 50-60Hz 

Weight (kg): 

6,8 

L: 

Measurements (cm) 

B:

H: 

16.5 
31.0 
27.7 

Code: 

4370 

*: Technical changes reserved. Values attained at  230 V / 50 Hz voltage. 

Summary of Contents for Tria 24 S

Page 1: ......

Page 2: ...Bedienungsanleitung Tria 24 S 24 SF Generator 2 HENSEL VISIT International GmbH ...

Page 3: ...a 24 S 24 SF Generator HENSEL VISIT GmbH Co KG 3 HENSEL VISIT GmbH Co KG Robert Bunsen Str 3 D 97076 Würzburg Lengfeld GERMANY Tel phone 49 0 931 27881 0 Fax 49 0 931 27881 50 E Mail info hensel de Internet http www hensel de ...

Page 4: ...nungsanleitung Tria 24 S 24 SF Generator 4 HENSEL VISIT GmbH Co KG Bedienungsanleitung Tria 24 S 24 SF Generator Stand 03 2011 Seite 5 User manual Tria 24 S 24 SF Power Pack Date of revision 2011 03 page 24 ...

Page 5: ...Firma HENSEL hat sich alle Mühe gegeben unter Einbeziehung und Beachtung aller gültigen Vorschriften ein sicheres und qualitativ hochwertiges Gerät zu fertigen Strenge Qualitätskontrollen stellen auch bei Großserien unseren Qualitätsmaßstab sicher Bitte tun Sie das Ihre hinzu und behandeln Sie die Geräte mit der notwendigen Sorgfalt Sollten Sie zur Nutzung Fragen haben stehen wir Ihnen jederzeit g...

Page 6: ...2 Absicherung 12 13 Blitzlampenanschluss 13 14 Anzahl Blitzlampen 14 Leistungsverteilung 14 Mechanischer Anschluss der Lampenstecker 14 Plugmatik 14 7 Betrieb 15 Ein und Ausschalten 15 Synchronisation 15 16 Funk optional 16 Testfunktion Leistungsregelung 17 Blitzbereitschaft 17 APD System 17 Einstelllicht 17 18 Audio 18 Fehlermeldungen 18 8 Wartung 18 19 Sicherungen austauschen 19 Turnusmäßige Übe...

Page 7: ...einem anderen Zweck benutzt werden als oben beschrieben insbesondere nicht für andere elektrische Anwendungen Der Kontakt mit der Kondensatorspannung ist lebens gefährlich deshalb dürfen das Öffnen des Generator gehäuses und Reparaturen nur von einem autorisierten Kundendienst vorgenommen werden Blitzröhren dürfen nur von autorisiertem geschultem Per sonal gewechselt werden Das Wechseln der Blitzr...

Page 8: ... Materialien wie Dekorationsstoffe papiere u ä nicht in unmittelbarer Umgebung der Genera toren und der Blitzlampen lagern um Brandgefahr zu ver meiden Generatoren sind vor Feuchtigkeit und Spritzwasser zu schützen Keine Zubehörteile anderer Hersteller anschließen auch wenn diese gleich oder ähnlich aussehen Generatoren an Scheren oder Decken hängend sind ge gen Herabfallen doppelt zu sichern Nich...

Page 9: ...O 3000 Blitzkopf 12 Reflektor 1 60 Sek 180 Abbrennzeit t 0 5 bei voller Blitzleistung 1x EH PRO 3000 2x EH PRO 3000 1 600s 1 1000s Ladezeit in Sek Max Min 2 2 0 45 Leistungseinstellung 6 f einstellbar in 1 10 f Leistungsabgabe 75 J 2400 J Leistungsverteilung symmetrisch Anzahl Blitzausgänge 2 Einstelllampe max Sicherung Einstelllampe 2 x 650 W 230V 10 AF Netzanschluss 230 V 50 60Hz Gewicht kg 6 8 ...

Page 10: ...AUS FULL PROP 11 READY Indikator Blitzbereitschaftsanzeige 12 TEST manuelle Blitzauslösung 13a Blitzlampenbuchse 1 13b Blitzlampenbuchse 2 6 Inbetriebnahme Sicherheitshinweise beim Umgang mit angeschlossenen Blitzköpfen Wegen möglicher Beschädigung der Blitzröhre beim Han tieren ist es unbedingt erforderlich vor dem Einschalten des Blitzkopfes den entsprechenden Lichtformervorsatz Reflektor Softbo...

Page 11: ...es geschieht entweder durch die Sicherungsschraube am HENSEL Neiger oder U Bügel Es ist jedoch wegen geltender Sicherheitsvorschriften eine Zweitsicherung durch ein Stahl seil notwendig Dieses kann von der Firma HENSEL VISIT unter der Art Nr 769 bezogen werden Das Stahlseil ist durch den Griff auf der Rückseite des Blitzkopfes zu führen und durch eine geeignete Öse an der Abhängung zu sichern Wärm...

Page 12: ... Zeit in dem Raum stehen in dem er benutzt wird Dadurch werden evtl Kriech ströme durch Feuchtigkeitsniederschlag vermieden Aufstellung Tria 24 S 24 SF Generatoren können stehend betrieben werden Netzanschluss Das Typenschild befindet sich am Gehäuseboden Der Tria 24 S 24 SF Generator kann bei 230 V betrieben werden Blitzgeneratoren dürfen nur an geerdete Stromnetze an geschlossen werden Das mitge...

Page 13: ...geeignet ist Für den Anschluss an den Tria 24 S 24 SF Generator stehen Blitzköpfe der Serien EH PRO EH Pro Mini und MH zur Verfü gung Es ist unbedingt darauf zu achten dass der Blitzkopf ent sprechend der vom Generator abgegebenen Energie belast bar ist Minimum 3000 Ws Die zulässige Belastbarkeit wird mit einer Blitzkopferkennung im Stecker überwacht Wenn ein unzulässiger Kopf angeschlossen wird w...

Page 14: ...r Anschluss der Lampenstecker Vor Anschluss der Lampenstecker den Generator mit dem Hauptschalter 2 ausschalten Nur einwandfreie Stecker und Buchsen verwenden Der Lampenstecker wird durch eine mechanische Verrie gelung arretiert Hierzu den Stecker leicht nach vorne geneigt in die jeweilige Blitzbuchse 13a oder 13b einstecken und an schließend hinten beim Kabelausgang fest in die Verriege lung drüc...

Page 15: ... Schäden an der blitzauslösenden Kamera übernehmen Vor der Verwendung einer nicht marktüblichen Kamera sollte deshalb der Kamerahersteller kontaktiert werden Synchronisation über Fotozelle Der Generator kann auch über die eingebaute Fotozelle 7 ausgelöst werden Das Auslösen erfolgt dann durch das Auf treffen eines Blitzes welcher durch ein anderes Gerät abge geben wurde Diese Betriebsart wird durc...

Page 16: ...achten Schie beschalter wird ebenfalls einer der 3 Arbeitskanäle gewählt Bei Geräten mit eingebautem Funk optional erfolgt die Wahl der Funkkanäle durch Drücken des Leistungsreglers 9a 1x drücken und die Anzeige 9 wechselt auf die Funkkanäle OFF C1 C2 C3 bzw die FREEMASK Kanäle F1 F2 F3 Die Kanalwahl und das Ein Ausschalten des Funkempfängers er folgt durch Drehen des Leistungsreglers Ist der Funk...

Page 17: ...cherte Energie intern ab Dabei wird kein Blitz ausgelöst Abgeschaltete Generatoren werden automatisch entladen Einstelllicht Das Einstelllicht wird mit Taster 10 ein eine der darüberlie genden Kontroll LEDs leuchtet auf bzw ausgeschaltet Kon troll LED erlischt Das Einschalten des Einstelllichtes ist nur wirksam wenn der angeschlossene Blitzkopf seinerseits ein geschaltet bzw sein Einstelllicht auf...

Page 18: ...ch einen Signalton angezeigt Der Signalton wird durch Betätigung von Schalter 6 zugeschaltet Kontroll LED leuchtet auf Fehlermeldungen E1 Temperaturfehler Fehlermeldung aufgrund von Überhitzung Nach Abkühlung setzt sich die Meldung von selbst zurück und es kann weiter gearbeitet werden Bei Überhitzung das Gerät nicht ausschal ten um die Ventilatorkühlung zu ermöglichen E2 Ladefehler E3 Entladefehl...

Page 19: ...nesfalls dürfen Sicherungen geflickt oder überbrückt wer den Nur Sicherungen mit hohem Schaltvermögen nach IEC 127 2 1 bzw EN 60127 2 1 verwenden Keramikrohr Turnusmäßige Überprüfung Die nationalen Sicherheitsvorschriften verlangen eine inter vallmäßige Überprüfung und Wartung elektrischer Anlagen und Geräte Generatoren und Zubehör müssen regelmäßig auf ihre Betriebssicherheit überprüft werden Ein...

Page 20: ...r den Tria 24 S 24 SF Generator unter anderem zur Verfügung Blitzköpfe EH PRO EH Pro Mini und MH Serien Ringblitze LIGHTBAR 130 Flashboxen Funkfernauslösung Strobe Wizard Plus Spotlights Stabblitze Autolights und Megalights F Spot und vieles mehr Vor dem Anschließen von Blitzköpfen ist deren Maximal belastung zu beachten ...

Page 21: ...tgenstraße 8 D Tel 09306 3576 D 97295 Waldbrunn www blitzgeraeteservice baer de Müller TV Video Herbert Scholz Straße 11A Tel 09401 2217 D 93073 Neutraubling www mueller tv de Jürgen Skaletz Elektronik Service Dorfstraße 48 Tel 0511 799722 D 31916 Isernhagen www skaletz hannover de Arne Pohl Elektronik Service Sandbergstraße 29 Tel 02203 962754 D 51143 Köln Porz Langel esp pohl de Smakku GBR Holte...

Page 22: ...Bedienungsanleitung Tria 24 S 24 SF Generator 22 HENSEL VISIT International GmbH ...

Page 23: ...User manual Tria 24 S 24 SF Power Pack HENSEL VISIT International GmbH 23 ...

Page 24: ... manufacture a secure and high quality flash system under inclusion and ob servance of all current regulations Strict quality controls secure our quality requirements even in mass production Please take your part in this and treat the equipment with due care your reward will consist of excellent pictures If you should have any questions on the use then feel free to ask us at any time We wish you s...

Page 25: ...1 32 Lamp connections 32 Number of flash heads connected 33 Power distribution 33 Mechanical connection of lamp plugs 33 Plugmatic 33 7 Operation 33 Switching ON and OFF 33 Synchronization 34 35 Radio control optional 35 Flash power control 35 Flash readiness 36 APD System 36 Modeling lamp 36 37 Audio 37 Trouble shooting 37 8 Maintenance 37 38 Replacement of fuses 38 Regular check 38 Return to cus...

Page 26: ... Tria 24 S 24 SF power pack and repairs must only be made by authorized customer ser vice Flash tubes must only be exchanged by authorized trained personnel Exchange of flash tube and modeling lamp must only be performed with the appliance turned off unplugged from the mains and discharged Power packs must only be used on supply lines mains with working protective conductor earth line Only lamp co...

Page 27: ...cessories from other manufacturers even if they use the same or similar connectors Power packs hanging from pantographs or ceiling must be doubly secured against falling down Do not flash into eyes at short distances smaller than 5 m because this can lead to eye damage Do not look directly into the flash reflector the flash lamp could be triggered inadvertently Regularly air closed rooms to preven...

Page 28: ...h duration 1x EH PRO 3000 2x EH PRO 3000 t 0 5 in sec full power 1 600 1 1000 Recycling time Max in sec Min 2 2 0 45 Power adjustment 6 f adjustable in 1 10 f Power output 75 J 2400 J Power distribution symmetrical No of flash sockets 2 Modeling lamp Max Fuse 2 x 650 W 230 V 10 AF Mains voltage 230 V 50 60Hz Weight kg 6 8 L Measurements cm B H 16 5 31 0 27 7 Code 4370 Technical changes reserved Va...

Page 29: ... 9a Flash output control 10 LAMP Modeling lamp OFF ON PROP FULL 11 READY indicator indicator for flash readiness 12 TEST Manual flash release 13a Lamp socket 1 13b Lamp socket 2 6 Starting up Safety hints for operation with connected flash heads To avoid damage to the flash tube mount reflectors and light formers softboxes etc before use and turning on the unit Do not move power packs and lamp hea...

Page 30: ...m falling down This is done by tightening the safety screw on the HENSEL U bracket or the wrench screw on the HENSEL tilting head Due to the existing safety regulations it is however necessary to use a safety rope Code No 769 for further security The safety rope has to be led through the handle of the flash head and then secured by looping through the bracket on the pantograph or the eyelet on the...

Page 31: ...l shortcuts which might occur by conden sing water Positioning Tria 24 S 24 SF power packs can be operated standing up Mains connection The type label can be found at the bottom of the appliance Tria 24 S 24 SF power pack can be operated at 230 V mains voltage Flash power packs must only be connected to mains outlets with ground connection Insert the plug of the provided power cable into the mains...

Page 32: ...missible load capacity of a flash head will be controlled by a flash head plug code In case of connecting an inadmissible flash head to the power pack the code will block flash release Only flash head extension cables with the plug code must be used The cables can be ordered with precise specification from HENSEL VISIT Lamp heads flash heads with halogen lamps which are not equipped with a cooling...

Page 33: ...or this insert the plug into flash socket 13a or 13b slightly tilted forward and then press it tightly into the catch at the rear near the cable duct To disconnect the plug press back the catch and pull the plug upwards at the back at the cable duct Plugmatic The flash sockets 13 are fitted with the HENSEL safety system Plugmatic This enables unplugging and replugging the flash plugs without dange...

Page 34: ...in radio link let you select the radio chan nels by pushing the button 9a output regulator Push 1x and the display switches to the radio channels OFF C1 C2 C3 and respectively the FREEMASK channels F1 F2 F3 The channel selection and the on off setting of the radio receiver are done by turning the output regulator A dot blinks in the bottom right corner of the display when the radio function is swi...

Page 35: ...nt working channels can be selected or the All option The radio receiver is to be attached to the synchronization socket 4 of the power pack and the working channel selected Depending on the working channel selected the flash can be triggered by pressing the Test button 12 or releasing the camera shutter In case of choosing the All option on the transmitter all flash units are triggered independen...

Page 36: ...the flash head or the main switch must be switched on FULL When FULL mode is selected the maximum output of the modeling lamp is achieved independently from the flash output setting PROP To have proportionality between modeling lamp and flash power output the PROP mode must be selected When the maximum flash power output is reduced the maximum modeling lamp output is proportionally dimmed Dim mode...

Page 37: ...Audio Readiness to flash after charging is signaled with a tone This tone can be turned on control LED lights up or off using the AUDIO switch 6 Trouble shooting E1 Error message because of overheating automatic reset after a cooling down period Do not switch the unit off to allow fan cooling E2 Charging error E3 Discharging error E5 Internal error power supply voltage check Switch the power pack ...

Page 38: ...ia 24 S 24 SF power pack 10 AF quick Fuses for connected flash heads 230 V operation Regular check National safety regulations require regular inspection and maintenance of electrical systems and appliances Power packs and accessories must be checked regularly for safe operation Yearly inspection of the appliances serves the safety of the user and protects your investment in the system Return to c...

Page 39: ... trigger system Strobe Wizard Plus Spotlights Linear flashlight units Autolights and Megalights Before connecting flash heads their maximum load must be observed 11 Customer Service Works customer service with 24 hours express service HENSEL VISIT GmbH Co KG Service Department Robert Bunsen Str 3 D 97076 Würzburg Phone 49 0 931 27881 0 Fax 49 0 931 27881 50 International service addresses are avai...

Page 40: ...User manual Tria 24 S 24 SF Power Pack 40 HENSEL VISIT International GmbH ...

Page 41: ...User manual Tria 24 S 24 SF Power Pack HENSEL VISIT International GmbH 41 ...