User manual // EH Pro Mini / EH Pro Mini 1200 P (Speed) Flash Head
HENSEL-VISIT GmbH & Co. KG
35
Replacement of modeling lamp
Attention:
Turn the unit off and disconnect it from any power
supply before replacing the modeling light. Wait at
least 15 minutes before continuing the procedure and
until the halogen lamp has cooled off.
Depending on the mains circuit and the flash head
type, only the specified modeling lamps should be
used (see table above). When changing the modeling
lamp, please note that it will be secured by the
correct value.
Wait until the modeling lamp has cooled down, and then
carefully remove the glass dome from the head by pulling
it out of the spring mechanism (
see page 31
) and moving
it straight away from the head
without touching modeling
lamp or flash tube (danger!)
.
Handle the halogen lamp with care. Pull the halogen lamp
out and replace the modeling lamp with a new one.
As mentioned before, make sure that the right fuse is
applied in accordance to the modeling lamp in use.
Avoid handling the halogen lamp with your bare hands to
prevent contaminating the glass of the lamp with the oil of
your skin. This would reduce the operational life of the
lamp. Please use cotton gloves.
Replacement of flash tube
Both EH Pro Mini heads are equipped with a user-
replaceable flash tube.
Turn the unit off and disconnect it from any power
supply before replacing the flash tube. Wait at least 15
minutes before continuing the procedure and until
any remaining condenser voltage has dissipated.
Avoid handling the flash tube with your bare hands to
prevent contaminating the flash tube with the oil of
your skin. This would reduce the the operational life of
the flash tube. Please use cotton gloves.
Should the glass body of the flash tube be broken, do
not touch the electrodes under any circumstance! In