background image

 

 

 

Wide-Angle Projection Spot 3000 und 6000 

 

Dear customer, 

 

You  have  purchased  a  high  quality  spot  with  excellent  technical  features.  Please  read  and 

adhere to the instructions so that you will have the pleasure of using this unit for many years. 

 

Due  to  safety  reasons,  the  modeling  lamp  and  the  flash  tube  are  separately  packaged  and 

stored inside the spot. 

 

The entire lamp support can be pulled out. To carry this out, the small round button on the 

upper  right  hand  side  of  the  fan  has  to  be  slid  towards  the  cable  outlet.  The  lamp  support 

element then opens on one side. The package with the flash tube and the modeling lamp can 

be  removed.  The  flash  tube  and  modeling  lamp  then  have  to  be  inserted  into  the  lamp 

support. Please note: Both lamp and flash tube 

must never be touched with bare fingers. 

 

For safety, the following should be adhered to: 

 

1)

 

The mains lamp plug has to be disconnected from the generator in order to carry out any 

repair (exchanging the flash tube, modeling lamp, mirror, etc.) 

 

2)

 

The  Spot  should  only  be  connected  to  a  suitable  generator.  Please  read  the  information 

given on the label on the plug.  

When plugging and unplugging the plug, the generator has to be switched off completely.  

 

It goes without saying that units from different manufacturers must never be used together - 

even  if  they  have  identical  lamp  connections.  Only  units  which  have  been  adapted  and 

designed for this purpose by the manufacturer can be used. 

 

3)

 

The  flash  tube  must  be  inserted  completely  to  the  base.  Plug  the  flash  tube  firmly  and 

completely into the socket, so that perfect contact can be guaranteed.  

A flash tube can only be replaced with a corresponding original flash tube.  

 

When  removing  the  flash  tube,  touch  the  base,  not  the  glass  (danger  of  breakage!). 

Guarantee is not given on glass breakage. Please note pos. no. 2.  

 

This  spot  allows  for  complete  removal  of  the  lamp  support.  On  the  right  side  (over  the 

safety fuse) on the swiveling axis a small lever can be found. When the lever is slid to the 

left,  the  lamp  support  is  completely  released.  The  protective  earth  wiring  on  the  lamp 

support  can  now  be  carefully  pulled  off.  Their  assembly  is  done  in  reverse  order  (don’t 

forget the protective earth wire!). The advantage of this construction is that it is no longer 

necessary to send the entire spot to customer service for repair. 

 

4)

 

The  correct  fuse  for  the  modeling  lamp  has  to  be  used.  A  3.15  A  fast-acting  fuse  is 

originally supplied for the 650 W lamp - a 1 .6 A fast-acting fuse has to be used for a 300 

W modeling lamp. 

 

5)

 

When plugging the spot in, slightly slant forward and firmly press into the locked position at 

the cable outlet. Burnt, dirty or damaged contacts will inevitably lead to serious damages. 

Such  plug  connections  have  to  be  exchanged  immediately.  Plug  connections  have  to  be 

checked regularly.  

 

The spot must never be exposed to dripping or splash water. 

 

 

Summary of Contents for 3000

Page 1: ...endungszweck angepasst umgebaut 3 Korrektes Einsetzen der Blitzröhre bis zum Anschlag Die Blitzröhre bitte fest und vollständig in die Fassung einstecken damit ein optimaler Kontakt gewährleistet wird Bei Ersatz der Blitzröhre darf nur eine entsprechende Originalröhre verwendet werden Beim Herausnehmen der Blitzröhre diese nur am Sockel anfassen sonst Bruchgefahr Bei Glasbruch ist kein Garantieans...

Page 2: ...skenschieber gelöst 5 Zur Reinigung können diese Schieber durch Herausziehen dabei Schieber verkanten entnommen werden 6 Die Projektion von Dias ist nur mit Einschränkungen und einigen Tricks möglich Zur Scharfeinstellung darf das Einstelllicht nur kurzfristig und mit reduzierter Leistung verwendet werden Jeder Blitz darf nur in größeren Abstanden abgegeben werden und es ist unvermeidbar dass nach...

Page 3: ...nections Only units which have been adapted and designed for this purpose by the manufacturer can be used 3 The flash tube must be inserted completely to the base Plug the flash tube firmly and completely into the socket so that perfect contact can be guaranteed A flash tube can only be replaced with a corresponding original flash tube When removing the flash tube touch the base not the glass dang...

Page 4: ...tightening screw which is next to the masks has to be loosened 5 The masks can be removed by tilting for cleaning purpose 6 Projection of slides is only possible with certain reservations and special tricks For achieving correct focusing the modeling light should only be used at reduced capacity for a short time Flashing should only be done in longer intervals Otherwise the slide would get damaged...

Reviews: