Operating the device
48
Daily flash counter
Reading the daily flash counter
To read the daily flash counter, proceed as follows:
Press the AUDIO button for one second.
The number of triggered flashes appears on the display. The number range
of the daily flash counter extends up to 999.
Resetting the daily flash counter
To reset the daily flash counter, proceed as follows:
Press the AUDIO button for one second.
The number of triggered flashes appears on the display.
Press the rotary switch.
The daily flash counter is reset to zero.
Activating and deactivating “PM” mode
In case of operation at Power Max L, the device also functions with
particularly short flash durations and fast recycling times. This requires a
comparably high current consumption. To guarantee consistently optimum
functioning, the device must be switched to “PM” mode for operation at
Power Max L. In “PM” mode, the model light is permanently switched to
100 W and the “Flash Check” function is activated. To activate “PM” mode,
proceed as follows:
Connect the device to a Power Max L mains socket.
Switch on Power Max L.
Switch on the device.
Press the SLAVE button and keep it pressed until a beep sounds.
The display shows “bat” and the set energy output alternately. The LED
display above the button lights up green. “PM” mode is activated.
To deactivate “PM” mode, proceed as follows:
Press the SLAVE button and keep it pressed until a beep sounds.