Check the voltage at plug X4 on
the relay pcb. Switch the unit on.
Are 230V available at X4.2?
No
Is the safety switch ok?
(continuity test during the unit is
disconnected from the power
supply) ?
No
Replace safety limit switch
Is the power supply (phase L3)
available and fuse F3 ok?
No
Ensure power supply or
rather replace fuse F3.
Yes
Yes
Functional test from relay K1at
the relay pcb (Input X6.1; Output
X.6.2. Replace relay pcb if
necessary.
Yes
Check if the neutral conductor
(N) is available at plug X4.1.