![Henny Penny OFG-391 Operator'S Manual Download Page 58](http://html1.mh-extra.com/html/henny-penny/ofg-391/ofg-391_operators-manual_2124390058.webp)
Model OFG- 391
3-19. INFORMATION MODE
This mode gathers and stores historic information on the fryer and
operator’s performance. Press and at the same time
and “*INFO MODE*” shows on display. Press or
to access the steps and press to view the statistics within
each step. Information Mode is intended for technical use, but
the operator can view the following information:
1.
E-LOG
- last 10 errors and time they occurred
2.
LAST LOAD
- information about the most recent Cook
Cycle, or the cycle presently in progress
3.
DAILY STATS
- information for the last 7 days.
4.
REVIEW USAGE
- information accumulated since the
last time this data was manually reset
5.
INP A VHDSF PM.PM
- provides test of fryer inputs
6.
OUTP
- shows the state of heater and pressure
7.
OIL TMP
- temperature of shortening
8.
CPU TMP
- temperature of PC board
9.
ANALOG
- status of controller’s a-to-d converter
Press and hold to exit Information Mode at any
time, or after 2 minutes, controls automatically exit back to
normal operation.
1. E-LOG
(error code log)
Press and “1A” (date & time) “*NOW*” shows in
display. This is the present date and time.
Press and if a error was recorded, “1B” (date, time, and
error code information) shows in display. This is the latest
error code that the controls recorded.
Press and the next latest error code information can be
seen. Up to 10 error codes (1B to 1K) can be stored in the
E-LOG Section.
Press to continue to LAST LOAD.
3-38
703
Summary of Contents for OFG-391
Page 1: ...OPERATOR S MANUAL Henny Penny Open Fryer Gas Model OFG 391...
Page 2: ......
Page 12: ...Model OFG 391 OptionalRampUnloading 2 3 703...
Page 13: ...Model OFG 391 908 2 4...
Page 17: ...Model OFG 391 403 2 8...
Page 25: ...Model OFG 391 403 3 5 14 1 2 3 4 5 6 7 8 9 13 11 12 10 Figure 3 2...